BOMANTARA, AJI (2025) EVALUASI ELEMEN KOLOM PADA GEDUNG HOTEL NOVOTEL BSD TANGERANG DENGAN DAN TANPA DINDING GESER. S1 thesis, Universitas Mercu Buana Jakarta.
|
Text (HAL COVER)
01 Cover.pdf Download (494kB) | Preview |
|
![]() |
Text (BAB I)
02 BAB I.pdf Restricted to Registered users only Download (83kB) |
|
![]() |
Text (BAB II)
03 BAB II.pdf Restricted to Registered users only Download (392kB) |
|
![]() |
Text (BAB III)
04 BAB III.pdf Restricted to Registered users only Download (382kB) |
|
![]() |
Text (BAB IV)
05 BAB IV.pdf Restricted to Registered users only Download (1MB) |
|
![]() |
Text (BAB V)
06 BAB V.pdf Restricted to Registered users only Download (28kB) |
|
![]() |
Text (DAFTAR PUSTAKA)
07 DAFTAR PUSTAKA.pdf Restricted to Registered users only Download (82kB) |
|
![]() |
Text (LAMPIRAN)
08 Lampiran.pdf Restricted to Registered users only Download (573kB) |
Abstract
High-rise building construction in Indonesia is vulnerable to earthquakes, which generate significant lateral forces. Shear walls are an effective solution for improving the stiffness, capacity, stability, and safety of structures against these lateral forces. This study aims to evaluate changes in column behavior in the Novotel BSD Tangerang Hotel Building with and without shear walls. The analysis uses ETABS V.18.0.0, referencing SNI 1726-2019, SNI 1727-2020, and SNI 2847- 2019. The results show that the presence of shear walls significantly reduces the internal forces in the columns. For example, Column C8 experienced a decrease in maximum axial force from 2749.87 kN to 1888.78 kN, and the maximum bending moment decreased from 2504.39 kNm to 2011.02 kNm. All columns still meet the safety standards of SNI 2847:2019, indicating an increase in safety margins. This study emphasizes the importance of shear walls in enhancing structural performance and reducing the risk of column failure due to lateral loads. Overall, the presence of shear walls has proven to be highly effective in improving the seismic performance of the Novotel BSD Tangerang Hotel Building, making it stiffer, more stable, and safer against earthquake loads. Keywords : Column, Shear Wall, Earthquake, ETABS, Novotel BSD Building Pembangunan gedung bertingkat di Indonesia rentan terhadap gempa bumi, yang menghasilkan gaya lateral signifikan. Dinding geser menjadi solusi efektif untuk meningkatkan kekakuan, kapasitas, stabilitas, dan keamanan struktur terhadap gaya lateral ini. Penelitian ini bertujuan untuk mengevaluasi perubahan perilaku elemen kolom pada Gedung Hotel Novotel BSD Tangerang dengan dan tanpa dinding geser. Analisis menggunakan ETABS V.18.0.0, mengacu pada SNI 1726-2019, SNI 1727-2020, dan SNI 2847-2019. Hasil menunjukkan bahwa dengan adanya dinding geser mengurangi gaya dalam pada kolom secara signifikan. Seperti pada kolom C8 mengalami penurunan gaya aksial maksimum dari 2749.87 kN menjadi 1888.78 kN, dan momen lentur maksimum berkurang dari 2504.39 kNm menjadi 2011.02 kNm. Semua kolom tetap memenuhi standar keamanan SNI 2847:2019, menunjukkan peningkatan margin keamanan. Penelitian ini menegaskan pentingnya dinding geser dalam meningkatkan kinerja struktural dan mengurangi risiko kegagalan kolom akibat beban lateral. Secara keseluruhan, dengan adanya dinding geser terbukti sangat efektif dalam meningkatkan kinerja seismik Gedung Hotel Novotel BSD Tangerang menjadikannya lebih kaku, stabil, dan aman terhadap beban gempa. Kata Kunci : Kolom, Dinding Geser, Gempa Bumi, ETABS, Gedung Novotel BSD
Actions (login required)
![]() |
View Item |