NUGROHO, MUHAMMAD FAISAL CAHYA (2020) ANALISA GAS TERLARUT (DGA) UNTUK MENDETEKSI KEGAGALAN PADA TRANSFORMATOR DISTRIBUSI. S1 thesis, Universitas Mercu Buana Bekasi.
|
Text
01) Halaman Judul.pdf Download (26kB) | Preview |
|
|
Text
02) Abstrak.pdf Download (25kB) | Preview |
|
|
Text
03) Lembar Pernyataan.pdf Download (49kB) | Preview |
|
|
Text
04) Lembar Pengesahan.pdf Download (218kB) | Preview |
|
|
Text
06) Daftar isi.pdf Download (30kB) | Preview |
|
|
Text
05) Kata Pengantar.pdf Download (100kB) | Preview |
|
|
Text
07) Daftar gambar.pdf Download (28kB) | Preview |
|
|
Text
08) Daftar tabel.pdf Download (25kB) | Preview |
|
Text
09) BAB I.pdf Restricted to Registered users only Download (110kB) |
||
Text
10) BAB II.pdf Restricted to Registered users only Download (870kB) |
||
Text
11) BAB III.pdf Restricted to Registered users only Download (182kB) |
||
Text
12) BAB IV.pdf Restricted to Registered users only Download (1MB) |
||
Text
13) BAB V.pdf Restricted to Registered users only Download (102kB) |
||
Text
14) Daftar Pustaka.pdf Restricted to Registered users only Download (53kB) |
||
Text
15) Lampiran.pdf Restricted to Registered users only Download (1MB) |
Abstract
ABSTRAK Transformator distribusi sangat penting perannya karena sebagai jantungnya disribusi tenaga listrik. Permasalahannya adalah kita harus dapat mengantisipasi apabila transformator terdapat gangguan. Dalam penelitian ini mengambil sempel tiga transformator dengan dua kali uji DGA. Melalui uji DGA, kegagalan pada transformator dapat dideteksi berdasarkan gas-gas hidrokarbon yaitu H2, CO2, CO, C2H6, C2H4, CH4. Jumlah dari gas-gas tersebut akan dianalisis menggunakan metode TDCG, Key Gases, Roger Ratio dan Duval Triangle. Hasil analisa, ketiga transformator mengalami kegagalan pemanasan lebih yang bersumber dari gulungan sehingga timbul gas hidrogen dalam jumlah besar. Namun gangguan tersebut tidak berdampak pada kualitas listrik yang dihasilkan sehingga kegagalan dapat terjadi tanpa disadari. Oleh karenanya direkomendasikan untuk melakukan tes DGA berkala untuk mengantisipasi kegagalan transformator. Kata kunci : Transformator, Dissolved Gas Analysis, DGA Total Dissolved Combustible Gas (TDCG), Key Gases, Roger Ratio, Duval Triangle The distribution transformer is very important because it is the heart of the distribution of electricity. The problem is we have to be able to anticipate if there is a disturbance transformer. In this research, take three transformer samples with two DGA tests. Through the DGA test, the failure of the transformer can be detected based on hydrocarbon gases namely H2, CO2, CO, C2H6, C2H4, CH4. The amount of these gases will be analyzed using the TDCG, Key Gases, Roger Ratio and Duval Triangle methods. Based on the results of analysis and testing, the three transformers failed to overheat which originated from the windings resulting in large amounts of hydrogen gas. However, the interference does not have an impact on the quality of electricity generated so that failure can occur unnoticed. Therefore it is recommended to conduct periodic DGA tests to anticipate transformer failures. Keywords: Transformer, Dissolved Gas Analysis, DGA Total Dissolved Combustible Gas (TDCG), Key Gases, Roger Ratio, Duval Triangle
Item Type: | Thesis (S1) |
---|---|
Call Number CD: | FE/ELK 20 030 |
NIM/NIDN Creators: | 41417310031 |
Uncontrolled Keywords: | Kata kunci : Transformator, Dissolved Gas Analysis, DGA Total Dissolved Combustible Gas (TDCG), Key Gases, Roger Ratio, Duval Triangle |
Subjects: | 600 Technology/Teknologi > 620 Engineering and Applied Operations/Ilmu Teknik dan operasi Terapan > 621 Applied Physics/Fisika terapan > 621.3 Electrical Engineering, Lighting, Superconductivity, Magnetic Engineering, Applied Optics, Paraphotic Technology, Electronics Communications Engineering, Computers/Teknik Elektro, Pencahayaan, Superkonduktivitas, Teknik Magnetik, Optik Terapan, Tekn |