HAMDI, RAHMATUL (2020) PERANCANGAN ALAT MONITORING TEMPERATUR DAN KELEMBABAN RUANGAN JARAK JAUH SECARA REAL TIME. S1 thesis, Universitas Mercu Buana Jakarta.
|
Text (HAL COVER)
01 Cover.pdf Download (533kB) | Preview |
|
Text (BAB I)
02 Bab 1.pdf Restricted to Registered users only Download (108kB) |
||
Text (BAB II)
03 Bab 2.pdf Restricted to Registered users only Download (840kB) |
||
Text (BAB III)
04 Bab 3.pdf Restricted to Registered users only Download (788kB) |
||
Text (BAB IV)
05 Bab 4.pdf Restricted to Registered users only Download (669kB) |
||
Text (BAB V)
06 Bab 5.pdf Restricted to Registered users only Download (166kB) |
||
Text (DAFTAR PUSTAKA)
07 Daftar Pustaka.pdf Restricted to Registered users only Download (93kB) |
||
Text (LAMPIRAN)
08 Lampiran.pdf Restricted to Registered users only Download (1MB) |
Abstract
service life of a component and equipment in a room. According to the Decree of the Minister of Health of the Republic of Indonesia Number 1405 / Menkes / SK / XI / 2002 regarding Health Requirements for Office and Industrial Work Environment, the requirements for good indoor air have a Temperature with the range from 18℃ - 28℃ and Humidity of 40% - 60%. In the work area of Workshop 2 PT GMF Aeroasia, Tbk Unit TCE-1 Electrical Shop requires a stable temperature and humidity value. Currently technicians still use the manual method for monitoring and recording temperature and humidity values every hour, while the working hours of technicians in the workshop room only range from 8-9 working hours. It takes a tool that functions to monitoring and record temperature and humidity measurement values in real time connected using the internet network. Based on the average measurements of temperature and humidity monitoring tools using the DHT-22 sensor compared to the results of the hygrometer readings can be said to be good (good performance) with a temperature error percentage value of 1.94% and a percentage of humidity error of 4.09%. Keywords: Temperature and Humidity, Monitoring, Real Time, DHT-22 Sensor Pengaruh temperatur dan kelembaban sangat berpengaruh pada usia pakai suatu komponen dan equipment yang ada pada suatu ruangan. Menurut Keputusan Menteri Kesehatan Republik Indonesia Nomor 1405/Menkes/SK/XI/2002 mengenai Persyaratan Kesehatan Lingkungan Kerja Perkantoran dan Industri, bahwa persyaratan udara ruangan yang baik memiliki range suhu berkisar 18°C - 28°C dan kelembaban udara 40% - 60%. Pada area kerja Workshop 2 PT GMF Aeroasia, Tbk Unit TCE-1 Electrical Shop membutuhkan nilai temperatur dan kelembaban yang stabil. Saat ini teknisi masih menggunakan metode manual untuk monitoring dan merekam nilai temperatur dan kelembaban setiap jamnya, sedangkan jam kerja teknisi pada ruangan workshop hanya berkisar pada rentang 8-9 jam kerja. Maka diperlukan alat yang berfungsi untuk monitoring dan merekam nilai pengukuran temperatur dan kelembaban secara real time yang tehubung menggunakan jaringan Internet. Berdasarkan rata-rata perhitungan pengukuran alat monitoring temperatur dan kelembaban menggunakan sensor DHT-22 yang dibandingkan dengan hasil pembacaan hygrometer dapat dikatakan bagus (good performance) dengan nilai persentase error temperatur sebesar 1.94% dan persentase error kelembaban sebesar 4,09%. Kata kunci : Temperatur dan Kelembaban, Monitoring, Real Time, Sensor DHT- 22
Actions (login required)
View Item |