PENENTUAN NILAI KETIDAKPASTIAN HASIL KALIBRASI DAN IMPLEMENTASINYA PADA ALAT FURNACE

RAMDHANI, ABDURRAHMAN (2020) PENENTUAN NILAI KETIDAKPASTIAN HASIL KALIBRASI DAN IMPLEMENTASINYA PADA ALAT FURNACE. S1-Sarjana thesis, Universitas Mercu Buana Jatisampurna.

[img]
Preview
Text
1. Halaman Judul.pdf

Download (188kB) | Preview
[img]
Preview
Text
2. Lembar Pernyataan.pdf

Download (196kB) | Preview
[img]
Preview
Text
3. Lembar Pengesahan.pdf

Download (140kB) | Preview
[img]
Preview
Text
4. Abstrak.pdf

Download (104kB) | Preview
[img]
Preview
Text
5. Abstract.pdf

Download (104kB) | Preview
[img]
Preview
Text
6. Kata Pengantar.pdf

Download (161kB) | Preview
[img]
Preview
Text
7. Daftar Isi.pdf

Download (215kB) | Preview
[img]
Preview
Text
8. Daftar Tabel.pdf

Download (107kB) | Preview
[img]
Preview
Text
9. Daftar Gambar.pdf

Download (103kB) | Preview
[img]
Preview
Text
10. Daftar Lampiran.pdf

Download (103kB) | Preview
[img] Text
11. BAB 1.pdf
Restricted to Registered users only

Download (162kB)
[img] Text
12. BAB 2.pdf
Restricted to Registered users only

Download (393kB)
[img] Text
13. BAB 3.pdf
Restricted to Registered users only

Download (288kB)
[img] Text
14. BAB 4.pdf
Restricted to Registered users only

Download (272kB)
[img] Text
15. BAB 5.pdf
Restricted to Registered users only

Download (291kB)
[img] Text
16. BAB 6.pdf
Restricted to Registered users only

Download (234kB)
[img] Text
17. Daftar Pustaka.pdf
Restricted to Registered users only

Download (162kB)
[img] Text
18. Lampiran.pdf
Restricted to Registered users only

Download (234kB)

Abstract

ABSTRAK Alat Furnace merupakan tungku panas berkapasitas 14L dengan pencapaian maksimum suhu 1200°C yang berfungsi dalam proses pengujian kadar abu di bahan karet dan pengujian lainnya. Proses pengujian dilakukan pada suhu 550°C ±10°C yang telah diatur dalam SNI/ISO 247 Penentuan Kadar Abu yang dipersyaratkan. Untuk menjaga performance suhu, maka perlu dilakukan control secara kontinu dan periodik agar penyimpangan suhu furnace dapat diketahui, selain perawatan mesin perlu juga dilakukan verifikasi terhadap suhu sebenarnya yang dinamakan aktifitas kalibrasi. Kalibrasi adalah suatu kegiatan dengan cara membandingkan suhu langsung dengan alat termokopel dan indikator suhu termometer digital. Kalibrasi diukur pada suhu yang digunakan yaitu 550°C, kalibrasi dilakukan dengan memperhatikan beberapa faktor diantaranya hasil kalibrasi alat, faktor lingkungan dan nilai resolusi furnace. Hasil dari kalibrasi furnace diperoleh nilai yang disebut koreksi dan ketidakpastian pengukuran, adalah nilai penyimpangan pembacaan alat dari nilai sebenarnya dan rentang suhu. Dari hasil kalibrasi alat diperoleh nilai koreksi = - 5.0°C dan ketidakpastian = ±1.2°C, artinya nilai aktual suhu furnace adalah = 550 + (-5.0) ±1.2 . Artinya bila nilai pembacaan indikator furnace sebesar 550°C, maka nilai sebenarnya adalah (543.8 ~ 546.2)°C. Jadi dengan melaksanakan kalibrasi furnace, bisa diketahui nilai aktual suhu furnace, sehingga bisa diambil tindakan terhadap nilai penyimpangan yang diketahui. Kata Kunci : Kalibrasi, Furnace, Ketidakpastian, Ketertelusuran, Kualitas, Statistik ABSTRACT Furnace is a heat furnace with a capacity of 14L with a maximum temperature of 1200 ° C that functions in the process of testing the ash content in rubber materials and other tests. The testing process is carried out at a temperature of 550 ° C ± 10 ° C which has been regulated in SNI / ISO 247 Determination of Ash Levels required. To maintain the temperature performance, it is necessary to control continuously and periodically so that furnace temperature deviations can be known, in addition to engine maintenance it is also necessary to verify the actual temperature called calibration activity. Calibration is an activity by comparing temperature directly with thermocouple devices and digital thermometer temperature indicators. Calibration is measured at the temperature used is 550 ° C, calibration is done by taking into account several factors including the results of the calibration tool, environmental factors and the value of the furnace resolution. The results of the furnace calibration obtained a value called correction and measurement uncertainty, is the value of the deviation reading from the actual value and temperature range. From the results of the calibration tool obtained correction value = -5.0 ° C and uncertainty = ± 1.2 ° C, meaning that the actual value of the furnace temperature is = 550 + (-5.0) ± 1.2. This means that if the reading value of the furnace indicator is 550 ° C, the actual value is (543.8 ~ 546.2) ° C. So by carrying out furnace calibration, it can be known the actual value of the furnace temperature, so that action can be taken on the known deviation values. Keywords : Calibration, Furnace, Uncertainty, Traceability, Quality, Statistic

Item Type: Thesis (S1-Sarjana)
Call Number CD: FT/IND 19 045
NIM: 41614320034
Uncontrolled Keywords: Kalibrasi, Furnace, Ketidakpastian, Ketertelusuran, Kualitas, Statistik
Subjects: 600 Technology/Teknologi > 670 Manufacturing/Manufaktur, Pabrik-pabrik
600 Technology/Teknologi > 680 Manufacture For Specific Uses/Industri Pembuatan produk untuk penggunaan tertentu
Divisions: Fakultas Teknik > Teknik Industri
Depositing User: Nasruddin Mansyur S.Hum
Date Deposited: 07 Nov 2020 05:41
Last Modified: 07 Nov 2020 05:41
URI: http://repository.mercubuana.ac.id/id/eprint/58014

Actions (login required)

View Item View Item