NASUTION, RISA HASANAH (2019) ANALISA PROTEKSI LOSS OF EXCITATION PADA GENERATOR DI PLTGU MUARA KARANG UNIT 1. S1 thesis, Universitas Mercu Buana Jakarta.
|
Text (HAL COVER)
1. HALAMAN JUDUL.pdf Download (26kB) | Preview |
|
|
Text (ABSTRAK)
5. ABSTRAK.pdf Download (284kB) | Preview |
|
|
Text (LEMBAR PERNYATAAN)
2. LEMBAR PERNYATAAN.pdf Download (70kB) | Preview |
|
|
Text (LEMBAR PENGESAHAN)
3. LEMBAR PENGESAHAN.pdf Download (70kB) | Preview |
|
|
Text (KATA PENGANTAR)
4. KATA PENGANTAR.pdf Download (238kB) | Preview |
|
|
Text (DAFTAR ISI)
6. DAFTAR ISI.pdf Download (173kB) | Preview |
|
|
Text (DAFTAR TABEL)
8. DAFTAR TABEL.pdf Download (165kB) | Preview |
|
|
Text (DAFTAR GAMBAR)
7. DAFTAR GAMBAR.pdf Download (167kB) | Preview |
|
|
Text (DAFTAR SIMBOL)
9. DAFTAR SIMBOL.pdf Download (323kB) | Preview |
|
Text (BAB I)
10. BAB I.pdf Restricted to Registered users only Download (228kB) |
||
Text (BAB II)
11. BAB II.pdf Restricted to Registered users only Download (792kB) |
||
Text (BAB III)
12. BAB III.pdf Restricted to Registered users only Download (501kB) |
||
Text (BAB IV)
13. BAB IV.pdf Restricted to Registered users only Download (461kB) |
||
Text (BAB V)
14. BAB V.pdf Restricted to Registered users only Download (218kB) |
||
Text (DAFTAR PUSTAKA)
16. DAFTAR PUSTAKA.pdf Restricted to Registered users only Download (239kB) |
||
Text (LAMPIRAN)
17. LAMPIRAN.pdf Restricted to Registered users only Download (580kB) |
Abstract
One of the operating disruptions that occ Engineeringur in the synchronous generator is the loss of excitation. Where this interference will cause the generated reactive power generator is reduced even lost so that the synchronous generator must absorb the reactive power of the system. If this condition occurs continuously can cause damage to the stator coil, will occur worsening insulation and the stator end iron so as to cause short circuit, or interruption of soil relations in the future. So to anticipate the impact of such disturbances required a protection system. The protection system used in PLTGU Muara Karang Unit 1 is a minimum reactance relay. This essay discusses how to determine the value of loss excitation protection setting using minimum reactance relay and offset relay mho so that synchronous generator can work optimally. From the research calculation the minimum reactance relay usage will work on XA-setting value zone (-2.55 pu) with 0.5 seconds delay time, XB-setting (offset) of -0.1156 pu with 0.5 seconds delay time. As for offset relay mho will work on zone 1 and zone 2 for offset value of -0.109 pu with delay time 0.1 second. As for zone 1 for the base impedance (