OPTIMASI PERFORMA X-RAY MOBILE LISTEM MOBIX1000 DI RUMAH SAKIT GADING PLUIT JAKARTA

SETYAWAN, THEODORUS EKO SIGIT (2020) OPTIMASI PERFORMA X-RAY MOBILE LISTEM MOBIX1000 DI RUMAH SAKIT GADING PLUIT JAKARTA. S1 thesis, Universitas Mercu Buana Bekasi.

[img]
Preview
Text
1 Halaman Judul.pdf

Download (49kB) | Preview
[img]
Preview
Text
2 abstrak.pdf

Download (90kB) | Preview
[img]
Preview
Text
3 Lembar Pernyataan.pdf

Download (762kB) | Preview
[img]
Preview
Text
4 Lembar Pengesahan.pdf

Download (645kB) | Preview
[img]
Preview
Text
6 daftar isi.pdf

Download (129kB) | Preview
[img]
Preview
Text
5 kata pengantar.pdf

Download (885kB) | Preview
[img]
Preview
Text
6 daftar isi.pdf

Download (129kB) | Preview
[img]
Preview
Text
7 daftar tabel.pdf

Download (89kB) | Preview
[img]
Preview
Text
8 daftar gambar.pdf

Download (85kB) | Preview
[img] Text
9 BAB I.pdf
Restricted to Registered users only

Download (52kB)
[img] Text
10 BAB II.pdf
Restricted to Registered users only

Download (260kB)
[img] Text
11 BAB III.pdf
Restricted to Registered users only

Download (297kB)
[img] Text
12 BAB IV.pdf
Restricted to Registered users only

Download (269kB)
[img] Text
13 BAB V.pdf
Restricted to Registered users only

Download (71kB)
[img] Text
14 Daftar Pustaka.pdf
Restricted to Registered users only

Download (44kB)

Abstract

ABSTRAK Pada saat ini telah banyak rumah sakit dan klinik yang menggunakan alat mobile X-Ray sebagai alat diagnosa pada organ tubuh manusia sehingga menuntut alat rontgen untuk memiliki performa yang baik ketika dioperasikan oleh tenaga medis. Ini dilakukan untuk memonitor kondisi parameter-parameter yang berhubungan dengan teknik pemeriksaan agar tetap konsisten sesuai kondisi yang diinginkan dan diperbolehkan. Dengan alat xray yang tidak optimal akan mengakibatkan kesalahan diagnosa yang diberikan oleh tenaga medis terhadap pasien dan radiasi yang diterima pasien maupun operator alat yang sangat besar. Dalam pengevalusian kelayakan nilai keluaran x-ray pada Rumah Sakit Gading Pluit Jakarta menggunakan dua metode, yaitu dengan metode pengukuran dengan menggunakan alat ukur Radcal dan perhitungan. Keluaran sinar-x yang baik harus memiliki akurasi tegangan tabung (KV) yaitu <10 %, akurasi waktu penyinaran (Secon) yaitu ≤ 10 %, kualitas berkas sinar-X (HVL) yaitu ≥ 2,3 mmAl, kebocoran tabung yaitu ≤ 1 mGy/jam. Hal ini akan menandakan bahwa sinar-x tersebut mempunyai performa yang baik. Kata Kunci: Uji Peforma Sinar-X, Keamanan Radiasi, Batas Toleransi ABSTRACT At this time there are many hospitals and clinics that use mobile X-Ray as a diagnostic tool on human organs so that they require X-ray equipment to have good performance when operated by medical personnel. This is done to monitor the condition of parameters related to inspection techniques to remain consistent with the desired and permissible conditions. With x-ray equipment that is not optimal will result in misdiagnosis provided by medical personnel to patients and radiation received by patients and operators of very large equipment. In evaluating the feasibility of the x-ray output value at Gading Pluit Hospital Jakarta using two methods, the measurement method using the Radcal measurement tool and the calculation method. A good x-ray output must have a tube voltage (KV) accuracy of <10%, an exposure time accuracy (Secon) of ≤ 10%, an X-ray beam (HVL) quality of ≥ 2.3 mmAl, and the tube leakage of mm 1 mGy / hour. This will indicate that the X-ray has good performance. Keywords: Test Performance X-ray, radiation safety, tolerance limit

Item Type: Thesis (S1)
Call Number CD: FE/ELK 20 025
NIM/NIDN Creators: 41418310034
Uncontrolled Keywords: Kata Kunci: Uji Peforma Sinar-X, Keamanan Radiasi, Batas Toleransi
Subjects: 600 Technology/Teknologi > 620 Engineering and Applied Operations/Ilmu Teknik dan operasi Terapan > 621 Applied Physics/Fisika terapan > 621.3 Electrical Engineering, Lighting, Superconductivity, Magnetic Engineering, Applied Optics, Paraphotic Technology, Electronics Communications Engineering, Computers/Teknik Elektro, Pencahayaan, Superkonduktivitas, Teknik Magnetik, Optik Terapan, Tekn
Divisions: Fakultas Teknik > Teknik Elektro
Depositing User: siti maisyaroh
Date Deposited: 15 Jun 2022 06:11
Last Modified: 15 Jun 2022 06:11
URI: http://repository.mercubuana.ac.id/id/eprint/63387

Actions (login required)

View Item View Item