SIMBOLON, HOKKOP (2020) ANALISA PENGARUH DAYA REAKTIF TERHADAP CAPASITOR BANK DI PT.VOKSEL ELEKTRIK TBK. S1 thesis, Universitas Mercu Buana Bekasi.
|
Text
1. HALAMAN JUDUL.pdf Download (166kB) | Preview |
|
|
Text
2. ABSTRAK.pdf Download (45kB) | Preview |
|
|
Text
3.LEMBAR PERNYATAAN.pdf Download (675kB) | Preview |
|
|
Text
4.LEMBAR PENGESAHAN.pdf Download (628kB) | Preview |
|
|
Text
Kata Pengantar.pdf Download (75kB) | Preview |
|
|
Text
6. DAFTAR ISI.pdf Download (52kB) | Preview |
|
|
Text
7. DAFTAR TABEL.docx.pdf Download (45kB) | Preview |
|
|
Text
8. DAFTAR GAMBAR.docx.pdf Download (92kB) | Preview |
|
Text
10. BAB 1.pdf Restricted to Registered users only Download (179kB) |
||
Text
11. BAB 2.pdf Restricted to Registered users only Download (777kB) |
||
Text
12. BAB 3.pdf Restricted to Registered users only Download (46kB) |
||
Text
13.BAB 4.pdf Restricted to Registered users only Download (714kB) |
||
Text
14. BAB 5.pdf Restricted to Registered users only Download (37kB) |
||
Text
16. DAFTAR PUSTAKA.pdf Restricted to Registered users only Download (38kB) |
Abstract
ABSTRAK Dalam penyaluran daya listrik ke pusat beban, faktor penyebab buruknya nilai power factor diakibatkan oleh pemakaian beban induktif , seperti motor listrik dan alat elektronik. Rendahnya power factor maka daya reaktif yang dihasilkan akan dikenakan denda oleh PLN. Kerugian daya yang disebabkan beban reaktif induktif bisa dikurangi dengan daya reaktif kapasitif yang bisa diperoleh dengan memasang rangkaian kapasitor (kapasitor bank) parallel dengan beban. Pada industri, Perlunya perbaikan faktor daya pada beban industri untuk meningkatkan efisiensi penggunaan daya aktif (Watt) sehingga bisa maksimal. Metode yang digunakan adalah metode segitiga daya untuk mengetahui besar daya semu, daya reaktif dan daya aktif. Setelah daya reaktif didapatkan maka dilakukan perbaikan nilai cos phi. Untuk menghitung besarnya daya reaktif dapat dilakukan melalui tabel kompensasi, tabel ini menyajikan suatu data dengan input faktor daya mula – mula sebesar Cos θ1 dan faktor daya yang diinginkan Cos θ2 maka besarnya faktor pengali dapat dilihat melalui tabel kompensasi. Penggunaan daya reaktif ini akan dikenakan biaya jika faktor dayanya dibawah 0,85 sesuai standar yang telah ditetapkan PT. PLN (persero). Untuk mengurangi bahkan menghilangkan biaya pemakaian kVAR tersebut dapat dilakukan melalui perbaikan faktor daya dengan pemasangan kapasitor bank pengkompensasi daya reaktif. Jika Power Factor < 0,85 (rendah) tentu kapasitas daya aktif (kW) yang dapat digunkan pelanggan akan berkurang. Dalam hal ini Peningkatan power factor dari 0,85 menjadi 0,96 sehingga didapatkan didapatkan peningkatan kualitas daya pada bulan April sebesar 939 kW dari 7.020 kW menjadi 7,958.77 kW dan Pengurangan Daya Reaktif sebesar 2,089 kVAr dari 4,411 kVAR menjadi 2,321.31 kVAR Kata Kunci : Power factor, Capasitor bank, daya reaktif ABSTRACT In the distribution of electric power to the load center, factors causing the poor value of the power factor are caused by the use of inductive loads, such as electric motors and electronic devices. The low power factor, the reactive power generated will be subject to fines by PLN. The power loss caused by the inductive reactive load can be reduced by the capacitive reactive power that can be obtained by installing a series of capacitors (capacitor banks) parallel to the load. In industry, the need improvement of power factor at industrial loads to improve usage efficiency active power (Watts) so that it can be maximized. The method used is the triangle power method to determine the apparent power, reactive power and active power. After reactive power is obtained, the cos cos value is improved. To calculate the magnitude of reactive power can be done through the compensation table, this table presents a data with an initial power factor input of Cos θ1 and the desired power factor Cos θ2 then the magnitude of the multiplier can be seen through the compensation table. The use of reactive power will be charged if the power factor is below 0.85 according to the standards set by PT. PLN (Persero). To reduce or even eliminate the cost of using kVAR can be done through the improvement of the power factor by installing a reactive power compensating bank capacitor. If the Power Factor <0.85 (low) of course the active power capacity (kW) that can be used by customers will be reduced. In this case an increase in power factor from 0.85 to 0.96 so that we get an increase in power quality in April by 939 kW from 7,020 kW to 7,958.77 kW and Reactive Power Reduction by 2,089 kVAr from 4,411 kVAR to 2,321.31 kVAR Keywords: Power factor, Capacitor bank, reactive power
Item Type: | Thesis (S1) |
---|---|
Call Number CD: | FE/ELK 20 022 |
NIM/NIDN Creators: | 41416320044 |
Uncontrolled Keywords: | Kata Kunci : Power factor, Capasitor bank, daya reaktif |
Subjects: | 600 Technology/Teknologi > 620 Engineering and Applied Operations/Ilmu Teknik dan operasi Terapan > 621 Applied Physics/Fisika terapan > 621.3 Electrical Engineering, Lighting, Superconductivity, Magnetic Engineering, Applied Optics, Paraphotic Technology, Electronics Communications Engineering, Computers/Teknik Elektro, Pencahayaan, Superkonduktivitas, Teknik Magnetik, Optik Terapan, Tekn |
Divisions: | Fakultas Teknik > Teknik Elektro |
Depositing User: | siti maisyaroh |
Date Deposited: | 07 Jun 2022 04:01 |
Last Modified: | 07 Jun 2022 04:01 |
URI: | http://repository.mercubuana.ac.id/id/eprint/62777 |
Actions (login required)
View Item |