MUNAJAT, MUHAMMAD UTOMO IBNU (2018) PENGARUH POSISI TANGGA TERHADAP GAYA GESER KOLOM SUDUT PADA STRUKTUR GEDUNG BERATURAN TAHAN GEMPA. S1 thesis, Universitas Mercu Buana Jakarta.
|
Text (HAL COVER)
1. Halaman Judul.pdf Download (35kB) | Preview |
|
|
Text (ABSTRAK)
2. Abstrak.pdf Download (30kB) | Preview |
|
|
Text (LEMBAR PERNYATAAN)
3. Surat Pernyataan.pdf Download (556kB) | Preview |
|
|
Text (LEMBAR PENGESAHAN)
4. Lembar Pengesahan.pdf Download (347kB) | Preview |
|
|
Text (KATA PENGANTAR)
5. Kata Pengantar.pdf Download (73kB) | Preview |
|
|
Text (DAFTAR ISI)
6. Daftar Isi.pdf Download (40kB) | Preview |
|
|
Text (DAFTAR TABEL)
7. Daftar Tabel.pdf Download (99kB) | Preview |
|
|
Text (DAFTAR GAMBAR)
8. Daftar Gambar.pdf Download (33kB) | Preview |
|
|
Text (DAFTAR LAMPIRAN)
9. Daftar Lampiran.pdf Download (22kB) | Preview |
|
Text (BAB I)
10. BAB 1.pdf Restricted to Registered users only Download (40kB) |
||
Text (BAB II)
11. BAB 2.pdf Restricted to Registered users only Download (492kB) |
||
Text (BAB III)
12. BAB 3.pdf Restricted to Registered users only Download (535kB) |
||
Text (BAB IV)
13. BAB 4.pdf Restricted to Registered users only Download (2MB) |
||
Text (BAB V)
14. BAB 5.pdf Restricted to Registered users only Download (44kB) |
||
Text (DAFTAR PUSTAKA)
15. Daftar Pustaka.pdf Restricted to Registered users only Download (27kB) |
||
Text (LAMPIRAN)
16. Lampiran.pdf Restricted to Registered users only Download (411kB) |
Abstract
Placement of stairs on building structures may result in some structural performance changes. At the time the structure experienced shocks due to the earthquake there will be torque on the structure. The placement of stairs away from the center of mass and the center of the stiffness of the structure may result in greater torsion. In this research, there will be 6 models of structural building structure which from each model will be placed ladder structure of different position. Then also will be given static and dynamic earthquake load whose parameters obtained from web http://puskim.pu.go.id/Aplikasi/desain_spektra_indonesia_2011/. The procedure of design of building structure refers to SNI SNI 1726: 2002 on Procedures for Planning of Earthquake For Building, SNI 1726: 2012 on Procedure of Planning of Building Structure and Non Building and SNI 2847: 2013 on Structural Concrete Requirements for Building. While the loading applied to the building structure refers to SNI 1727: 2013 on Minimum load for Design of Buildings and Other Structures and SKBI 1.3.53. 1987 on Load Planning for Houses and Buildings. And for structural analysis is done by using software ETABS v 9.6.0 to know the performance of each model. This research study was conducted to determine the effect of the position of the ladder to the shear forces that occur on the corner column. The hypothesis of this research is the placement of a good ladder is when placed in the center / near the center of mass and the center of the stiffness of the structure and the largest shear force in the column occurs when the ladder is placed at the corner of the structure. Keywords : Shear Forces, Regular Building, Column, Stairs Position, Torsion Penempatan tangga pada struktur bangunan dapat mengakibatkan beberapa perubahan kinerja struktur. Pada saat struktur mengalami guncangan akibat gempa maka akan terjadi torsi pada struktur tersebut. Penempatan tangga yang jauh dari pusat massa dan pusat kekakuan struktur dapat mengakibatkan torsi yang terjadi menjadi lebih besar. Pada penelitian ini, akan dibuat 6 buah model struktur gedung beraturan yang mana dari masing-masing model tersebut akan ditempatkan struktur tangga yang posisinya berbeda-beda. Kemudian juga akan diberikan beban gempa statis dan dinamis yang parameternya diperoleh dari web http://puskim.pu.go.id/Aplikasi/desain_spektra_indonesia_2011/. Prosedur perancangan struktur gedung mengacu pada SNI SNI 1726:2002 tentang Tata Cara Perencanaan Gempa Untuk Bangunan Gedung, SNI 1726:2012 tentang Tata Cara Perencanaan Struktur Bangunan Gedung dan Non Gedung dan SNI 2847:2013 tentang Persyaratan Beton Struktural Untuk Bangunan Gedung. Sedangkan pembebanan yang diaplikasikan pada struktur gedung mengacu pada SNI 1727:2013 tentang Beban Minimum Untuk Perancangan Bangunan Gedung dan Struktur Lain dan SKBI 1.3.53. 1987 tentang Perencanaan Pembebanan untuk Rumah dan Gedung. Dan untuk analisis struktur dilakukan dengan menggunakan software ETABS v 9.6.0 untuk mengetahui kinerja dari masing-masing model. Penelitian ini dilakukan untuk mengetahui pengaruh posisi tangga terhadap gaya geser yang terjadi pada kolom sudut struktur. Hipotesa dari penelitian ini adalah penempatan tangga yang baik yaitu saat ditempatkan ditengah/didekat pusat masa dan pusat kekakuan struktur dan gaya geser terbesar pada kolom terjadi saat tangga ditempatkan disudut struktur. Kata Kunci : Gaya Geser, Gedung Beraturan, Kolom, Posisi Tangga, Torsi
Actions (login required)
View Item |