SAPRUDIN, ERFIN MUHAMAD (2018) KAJIAN OTTV (Overall Thermal Transfer Value) SELUBUNG BANGUNAN (Studi Kasus Kantor Marketing Gallery Perumnas Sentraland Cengkareng, Jakarta Barat). S1 thesis, Universitas Mercu Buana Jakarta.
|
Text (HAL COVER)
01. Cover.pdf Download (42kB) | Preview |
|
|
Text (ABSTRAK)
02. Abstrak.pdf Download (100kB) | Preview |
|
|
Text (LEMBAR PERNYATAAN)
03. lembar pernyataan.pdf Download (786kB) | Preview |
|
|
Text (LEMBAR PENGESAHAN)
04. lembar pengesahan.pdf Download (818kB) | Preview |
|
|
Text (KATA PENGANTAR)
05. Kata Pengantar.pdf Download (78kB) | Preview |
|
|
Text (DAFTAR ISI)
06. Daftar Isi.pdf Download (180kB) | Preview |
|
|
Text (DAFTAR GAMBAR)
07. Daftar Gambar.pdf Download (174kB) | Preview |
|
|
Text (DAFTAR TABEL)
08. Daftar Tabel.pdf Download (171kB) | Preview |
|
|
Text (DAFTAR LAMPIRAN)
09. Daftar Lampiran.pdf Download (62kB) | Preview |
|
Text (BAB I)
10. Bab 1.pdf Restricted to Registered users only Download (199kB) |
||
Text (BAB II)
11. Bab 2.pdf Restricted to Registered users only Download (338kB) |
||
Text (BAB III)
12. Bab 3.pdf Restricted to Registered users only Download (593kB) |
||
Text (BAB IV)
14. Bab 4.pdf Restricted to Registered users only Download (929kB) |
||
Text (BAB V)
15. Bab 5.pdf Restricted to Registered users only Download (91kB) |
||
Text (DAFTAR PUSTAKA)
16. Daftar Pustaka.pdf Restricted to Registered users only Download (86kB) |
||
Text (LAMPIRAN)
17. Lampiran.pdf Restricted to Registered users only Download (1MB) |
Abstract
ABSTRACT Energy crisis is becoming a problem in the world even in Indonesia. The increasing need for buildings has resulted in greater energy consumption. But of every building that was founded, not much in the value of OTTV (Overall Thermal Transfer Value). Whereas OTTV is a heat transfer value criterion that can help save energy if heat transfer value is small. Because the least heat coming into the room over the building sheath will reduce the burden of the use of air conditioning. In this case the Architecture can play a role in the effort to control the energy crisis with energy conscious planning either in the initial planning of buildings or design solutions of existing buildings to be able to minimize energy consumption. Building Office Marketing Gallery Perumnas Sentraland is one of the 2 storey commercial buildings that have not known the value of OTTVnya. So in this case the researcher tried to assess the value of OTTV in the building, whether it meets the standard of BSNI that is equal to 35 Watt/m2. Then to find out what factors and factors that most influence the value of OTTV building and what efforts to reduce the value of OTTV. Methods of data collection using literature study and observation. In the observation using a tool wet & dry bulb hygrometer. While for data analysis using simulation and calculation method. From the result of the study, it is known that the total OTTV value of the building on the existing condition is 55,27 W/m2, which exceeds the standard of OTTV mandated by SNI that is 35 W/m2. As for the 4 orientation of the building, there is one orientation orientation that meets SNI. That is northwest orientation with OTTV value 28,92 W/m2. The factors that can affect the value of the building's OTTV are the absortation value (α), Shading Coefficient (SC) and Wall Window Ratio (WWR). However the factor that most affected the OTTV value of the building is WWR. This is because the façade of the building is dominated by glass.. Keyword: Energy Crisis, OTTV, Building Sheet, Office ABSTRAK Krisis energi sedang menjadi permasalahan didunia bahkan di Indonesia. Kebutuhan akan bangunan yang semakin meningkat mengakibatkan konsumsi energi pun menjadi besar. Namun dari setiap bangunan yang didirikan, belum banyak di ketahui nilai OTTV (Overall Thermal Transfer Value). Padahal OTTV merupakan kriteria nilai perpindahan panas yang dapat membantu penghematan energi jika nilai perpindahan panas itu kecil. Karena sedikitnya panas yang masuk kedalam ruangan melului selubung bangunan akan mengurangi beban penggunaan pendingin ruangan. Dalam hal ini Arsitektur dapat berperan dalam upaya pengendalian krisis energi dengan perencanaan yang sadar energi baik secara perencanaan awal bangunan atau solusi desain dari bangunan yang ada untuk dapat meminimalkan konsumsi energi. Bangunan Kantor Marketing Gallery Perumnas Sentraland merupakan salah satu bangunan komersil 2 lantai yang belum diketahui nilai OTTVnya. Maka dalam hal ini peniliti mencoba mengkaji nilai OTTV pada bangunan tersebut, apakah sudah memenuhi standar BSNI yaitu sebesar 35 Watt/m2. Kemudian untuk mengetahui faktor-faktor apa saja dan faktor yang paling mempengaruhi nilai OTTV bangunan tersebut dan upaya apa untuk mengurangi nilai OTTV tersebut. Metode pengumpulan data dengan menggunakan studi pustaka dan observasi. Dalam observasi tersebut menggunakan alat bantu wet & dry bulb hygrometer. Sedangkan untuk analisa data menggunakan metode simulasi dan kalkulasi. Dari hasil kajian tersebut diketahui nilai OTTV keseluruhan bangunan pada kondisi existing 55,27 W/m2, yang mana melebihi standar OTTV yang disaratkan SNI yaitu 35 W/m2. Adapun dari 4 orientasi bangunan tersebut, terdapat satu arah orientasi yang memenuhi SNI. Yaitu orientasi barat laut dengan nilai OTTV 28,92 W/m2. Adapun Faktor-faktor yang dapat mempengaruhi nilai OTTV bangunan tersebut diantaranya adalah nilai absortasi (α), Shading Koefisien (SC) dan Wall Window Ratio (WWR). Namun faktor yang paling mempengaruhi nilai OTTV bangunan tersebut adalah WWR. Ini dikarenakan pada façade bangunan tersebut di dominasi oleh kaca. Kata Kunci : Krisis Energi, OTTV, Selubung Bangunan, Kantor