RIYADI, MUHAMMAD RIDHO (2026) ANALISIS DAN IMPLEMENTASI MULTIHUB LOAD BALANCING PCC PADA SCADA 20 kV. S1 thesis, Universitas Mercu Buana Jakarta.
|
Text (HAL COVER)
Cover.pdf Download (584kB) | Preview |
|
|
Text (BAB I)
BAB 1.pdf Restricted to Registered users only Download (114kB) |
||
|
Text (BAB II)
BAB 2.pdf Restricted to Registered users only Download (79kB) |
||
|
Text (BAB III)
BAB 3.pdf Restricted to Registered users only Download (51kB) |
||
|
Text (BAB IV)
BAB 4.pdf Restricted to Registered users only Download (828kB) |
||
|
Text (BAB V)
BAB 5.pdf Restricted to Registered users only Download (65kB) |
||
|
Text (DAFTAR PUSTAKA)
DAFPUS.pdf Restricted to Registered users only Download (85kB) |
||
|
Text (LAMPIRAN)
LAMPIRAN.pdf Restricted to Registered users only Download (451kB) |
Abstract
The development of Supervisory Control and Data Acquisition (SCADA) systems in 20 kV electrical power distribution networks requires a stable and highly available communication infrastructure to support real-time monitoring and control processes. In the SCADA network within the UP3 Menteng and UP3 Cengkareng operational areas, an imbalance in traffic distribution across multiple Internet Service Provider (ISP) links was identified, causing network traffic to be concentrated on a single link and potentially reducing communication quality. This study aims to analyze and implement multihub load balancing using the Per Connection Classifier (PCC) method to improve traffic distribution, network Quality of Service (QoS), and the reliability of the failover mechanism in the 20 kV SCADA system. The evaluation was conducted by comparing network conditions before and after the implementation of PCC across three ISP links using throughput, delay, packet loss, traffic distribution, failover, and availability as performance parameters. The results show that traffic, which was previously concentrated on ISP-A at 95.7%, became more evenly distributed after PCC implementation, with 34.6% on ISP-A, 32.5% on ISP-B, and 32.9% on ISP-C, while the Jain's Fairness Index increased from 0.364 to 0.999. The average throughput increased from 19.38 Mbps to 42.24 Mbps, delay decreased from 46.17 ms to 17.89 ms, and packet loss decreased from 2.60% to 0.40%. Failover testing achieved a 100% successful traffic-switching rate with a recovery time of 4 seconds, while network availability increased from 97.82% to 99.94%. Based on these results, the implementation of the PCC method in a multihub load balancing scheme effectively improves traffic distribution, QoS performance, and the reliability and continuity of communication in the 20 kV SCADA network. Keywords: SCADA 20 kV, Load Balancing, Per Connection Classifier (PCC), Quality of Service, Failover, Availability Perkembangan sistem Supervisory Control and Data Acquisition (SCADA) pada jaringan distribusi tenaga listrik 20 kV membutuhkan infrastruktur komunikasi yang stabil dan memiliki tingkat ketersediaan tinggi untuk mendukung proses monitoring dan pengendalian secara real-time. Pada jaringan SCADA di area UP3 Menteng dan UP3 Cengkareng ditemukan ketidakseimbangan distribusi trafik pada beberapa jalur Internet Service Provider (ISP), sehingga trafik terkonsentrasi pada salah satu jalur dan berpotensi menurunkan kualitas komunikasi jaringan. Penelitian ini bertujuan untuk menganalisis dan mengimplementasikan multihub load balancing menggunakan metode Per Connection Classifier (PCC) dalam meningkatkan pemerataan distribusi trafik, kualitas layanan jaringan (Quality of Service/QoS), serta keandalan mekanisme failover pada sistem SCADA 20 kV. Pengujian dilakukan dengan membandingkan kondisi jaringan sebelum dan sesudah implementasi PCC pada tiga jalur ISP dengan parameter throughput, delay, packet loss, distribusi trafik, failover, dan availability. Hasil penelitian menunjukkan bahwa distribusi trafik yang sebelumnya terkonsentrasi pada ISP-A sebesar 95,7% menjadi lebih merata setelah implementasi PCC, yaitu 34,6% pada ISP-A, 32,5% pada ISP-B, dan 32,9% pada ISP-C, dengan nilai Jain's Fairness Index meningkat dari 0,364 menjadi 0,999. Rata-rata throughput meningkat dari 19,38 Mbps menjadi 42,24 Mbps, delay menurun dari 46,17 ms menjadi 17,89 ms, dan packet loss menurun dari 2,60% menjadi 0,40%. Pengujian failover menunjukkan tingkat keberhasilan pengalihan trafik sebesar 100% dengan recovery time 4 detik, sedangkan availability jaringan meningkat dari 97,82% menjadi 99,94%. Berdasarkan hasil tersebut, implementasi metode PCC pada skema multihub load balancing mampu meningkatkan pemerataan trafik, performa QoS, serta keandalan dan kontinuitas komunikasi jaringan SCADA 20 kV. Kata Kunci: SCADA 20 kV, Load Balancing, Per Connection Classifier (PCC), Quality of Service, Failover, Availability
Actions (login required)
![]() |
View Item |