HAFIDH, FAIZ SULTHAN AL (2025) ANALISIS VARIASI BEBAN TERHADAP KONSUMSI ENERGI PADA KOMPRESOR SENTRIFUGAL DI PERUSAHAAN YANG BERGERAK PADA BIDANG PULP & PAPER. S1 thesis, Universitas Mercu Buana Jakarta.
|
Text (HAL COVER)
01 cover.pdf Download (733kB) | Preview |
|
![]() |
Text (BAB I)
02 bab I.pdf Restricted to Registered users only Download (186kB) |
|
![]() |
Text (BAB II)
03 bab II.pdf Restricted to Registered users only Download (472kB) |
|
![]() |
Text (BAB III)
04 bab III.pdf Restricted to Registered users only Download (380kB) |
|
![]() |
Text (BAB IV)
05 bab IV.pdf Restricted to Registered users only Download (911kB) |
|
![]() |
Text (BAB V)
06 bab V.pdf Restricted to Registered users only Download (173kB) |
|
![]() |
Text (DAFTAR PUSTAKA)
07 daftar pustaka.pdf Restricted to Registered users only Download (215kB) |
Abstract
The compressor is a critical equipment for PT.XXX, which operates in the paper and cardboard fabrication industry, as the majority of its production machines use pneumatic systems. The factory uses a centrifugal compressor to generate compressed air for its production machines, operating 24/7 for 7 days a week. As a result, the energy consumption of the compressor requires special attention. Therefore, an analysis was conducted to compare the compressor's efficiency with variations in load levels. The research method was carried out experimentally by collecting load and energy consumption data for several compressor workload variations. The research findings revealed that the load variation on the centrifugal compressor affects its energy consumption. The trend shows that as the load increases, the energy consumption also increases, and vice versa. Similarly, when the workload is lower or deviates from the optimal load, the energy consumption also increases. The optimal workload level with the lowest energy consumption was found to be at 7.25 Bar, with an electrical energy consumption of 361.86 kW. On the other hand, the highest energy consumption was recorded at 7.00 Bar, with an electrical energy consumption of 365.34 kW. The polytropic efficiency value also influences energy usage. Similar to the load variation, the higher or lower the workload deviates from the optimal point, the lower the polytropic efficiency becomes. The highest polytropic efficiency value was observed at a load of 7.55 Bar, with a polytropic efficiency of 84.54%, while the lowest polytropic efficiency was recorded at a load of 7.00 Bar, with a polytropic efficiency of 73.82%. There is a wastage of up to 76,313.128 kWh/year (Rp. 99,207,068 per year) by reducing the pressure from 7.80 Bar to 7.25 Bar. Keywords: Centrifugal Compressor, Energy Consumption, Load Variation, Compressor Efficiency. Kompresor merupakan equipment yang sangat kritikal bagi PT.XXX yang bergerak di bidang fabrikasi kertas dan karton karena mayoritas mesin produksinya menggunakan sistem pneumatic. Pabrik ini menggunakan kompresor sentrifugal untuk memproduksi udara bertekanan bagi mesin-mesin produksinya selama 7 hari 24 jam terus menerus. Akibatnya, konsumsi energi kompresor harus mendapatkan perhatian khusus. Terkait hal tesebut dilakukanlah analisis dengan membandingkan efisiensi kerja kompresor terhadap variasi tingkat pembebanan. Metode penelitian dilakukan secara eksperimental melalui pengumpulan data beban dan konsumsi energi pada beberapa variasi beban kerja kompresor. Hasil dari penelitian ini didapatkan variasi beban pada kompresor sentrifugal akan mempengaruhi konsumsi energi pada kompresor, trend-nya semakin besar beban yang digunakan maka semakin besar juga konsumsi energi yang dihasilkan atau semakin kecil beban yang digunakan atau semakin rendah dari beban optimum maka konsumsi energi nya juga akan semakin besar, tingkat beban kerja optimal dengan konsumsi energi paling rendah ada di angka 7.25 Bar dengan konsumsi energi listrik sebesar 361.86 kW dan konsumsi energi paling tinggi berada di angka 7.00 Bar dengan konsumsi energi listrik sebesar 365.34 kW. Nilai efisiensi polytopik juga mempengaruhi penggunaan energi, sama dengan variasi beban, semakin tinggi atau semakin rendah beban yang digunakan dari titik optimal maka efisiensi polytropiknya akan semakin kecil. Nilai efisiensi polytropik tertinggi terdapat pada beban 7.55 Bar dengan nilai efisiensi polytropik sebesar 84.54% dan nilai efisiensi politropik terendah pada beban 7.00 bar dengan nilai efisiensi polytropik 73.82%. Terjadi pemborosan hingga 30,525.25 kWH/tahun (Rp. 39,682,827 per tahun) dengan menurunkan tekanan 7.80 Bar ke 7.25 Bar. Kata Kunci: Kompresor Sentrifugal, Konsumsi Energi, Variasi beban, Efisiensi Kompresor
Actions (login required)
![]() |
View Item |