IDENTIFIKASI KERUSAKAN KOIL SISTEM PENGAPIAN PADA KENDARAAN MPV 1000 CC DENGAN MENGGUNAKAN METODE HILBERT TRANSFORM

SAPUTRA, DAYU ANDRYAS (2023) IDENTIFIKASI KERUSAKAN KOIL SISTEM PENGAPIAN PADA KENDARAAN MPV 1000 CC DENGAN MENGGUNAKAN METODE HILBERT TRANSFORM. S1 thesis, Universitas Mercu Buana Jakarta.

[img]
Preview
Text (COVER)
01 COVER.pdf

Download (301kB) | Preview
[img]
Preview
Text (ABSTRAK)
02 ABSTRAK.pdf

Download (297kB) | Preview
[img] Text (BAB I)
03 BAB 1.pdf
Restricted to Registered users only

Download (114kB)
[img] Text (BAB II)
04 BAB 2.pdf
Restricted to Registered users only

Download (505kB)
[img] Text (BAB III)
05 BAB 3.pdf
Restricted to Registered users only

Download (769kB)
[img] Text (BAB IV)
06 BAB 4.pdf
Restricted to Registered users only

Download (1MB)
[img] Text (BAB V)
07 BAB 5.pdf
Restricted to Registered users only

Download (262kB)
[img] Text (DAFTAR PUSTAKA)
08 DAFTAR PUSTAKA.pdf
Restricted to Registered users only

Download (198kB)
[img] Text (LAMPIRAN)
09 LAMPIRAN.pdf
Restricted to Registered users only

Download (1MB)

Abstract

The coil is the main component of the vehicle in the ignition system and to maintain the performance of the coil so that it functions properly, it is necessary to analyze it through a vibration test. In this study, vibration tests were carried out and analyzed using a new method, namely the Hilbert Transform. Vibration testing was carried out on a 1000 CC MPV vehicle with rotational variations of 800rpm, 1500rpm, 2500rpm and 3500rpm. Vibration testing is carried out using an Accelerometer sensor connected to the FFT Analyzer to measure the acceleration amplitude of the vibration. Then the data from the test results were analyzed using Matlab and Hilbert Transform. At a rotational speed of 1500rpm, the measurement results obtained on the engine appear the first shape mode at a frequency of 45 Hz with an amplitude of 1,223 mm/s2 under normal conditions. Whereas in abnormal conditions a shape mode appears at a frequency of 41 Hz with an amplitude of 1,944 mm/s2. In abnormal conditions it indicates the occurrence of a bearing defect, because it occurs at 4x rpm. Furthermore, at a rotational speed of 2500 rpm the measurement results show that the first shape mode appears at a frequency of 48 Hz with an amplitude of 2.256 mm/s2 in normal coil conditions. Meanwhile, in abnormal conditions, a frequency shape mode of 41 Hz appears with an amplitude of 4,176 mm/s2. In abnormal conditions it indicates the occurrence of losses, because it occurs at 2x rpm. Then an analysis was carried out using the Hilbert Transform, from the results of the Restoring Force rotational speed of 800rpm, it showed that the abnormal condition was y = −2.4

Item Type: Thesis (S1)
Call Number CD: FT/MSN. 23 116
Call Number: ST/13/23/057
NIM/NIDN Creators: 41318110030
Uncontrolled Keywords: Koil pengapian; MPV; FFT; MATLAB; Metode Hilbert Transform
Subjects: 600 Technology/Teknologi > 620 Engineering and Applied Operations/Ilmu Teknik dan operasi Terapan
600 Technology/Teknologi > 620 Engineering and Applied Operations/Ilmu Teknik dan operasi Terapan > 621 Applied Physics/Fisika terapan > 621.8 Machine Engineering, Machinery/Teknik Mesin
Divisions: Fakultas Teknik > Teknik Mesin
Depositing User: Sekar Mutiara
Date Deposited: 23 Sep 2023 07:53
Last Modified: 23 Sep 2023 07:53
URI: http://repository.mercubuana.ac.id/id/eprint/80928