RAHAYU, JODI MAULANA PUJI (2026) PERANCANGAN ULANG STRUKTUR ATAS GEDUNG DATA CENTER DAN KANTOR DI JAKARTA SELATAN. S1 thesis, Universitas Mercu Buana Jakarta.
|
Text (HAL COVER)
COVER.pdf Download (976kB) | Preview |
|
|
Text (BAB I)
BAB I.pdf Restricted to Registered users only Download (217kB) |
||
|
Text (BAB II)
BAB II.pdf Restricted to Registered users only Download (1MB) |
||
|
Text (BAB III)
BAB III.pdf Restricted to Registered users only Download (736kB) |
||
|
Text (BAB IV)
BAB IV.pdf Restricted to Registered users only Download (2MB) |
||
|
Text (BAB V)
BAB V.pdf Restricted to Registered users only Download (502kB) |
||
|
Text (DAFTAR PUSTAKA)
DAFTAR PUSTAKA.pdf Restricted to Registered users only Download (155kB) |
||
|
Text (LAMPIRAN)
LAMPIRAN.pdf Restricted to Registered users only Download (965kB) |
Abstract
The structural design of a data center and office building requires a system that satisfies strength, stiffness, stability, ductility, and resistance to gravity and seismic loads in accordance with applicable standards. This study aims to design the superstructure of a data center and office building in South Jakarta based on SNI 1726:2019, SNI 1727:2020, SNI 2847:2019, and SNI 2052:2024, determine an appropriate structural system, evaluate structural response, and design reinforcement detailing. Structural analysis was performed using a threedimensional model in ETABS v21 with the Response Spectrum Analysis method. The results show that all superstructure components, including slabs, beams, columns, and shear walls, satisfy the adopted design requirements. The building exhibits no horizontal or vertical irregularities, with fundamental periods of 1.214 s in the X-direction and 1.246 s in the Y-direction, and cumulative modal mass participation reaching 100% in both directions. The response spectrum analysis satisfies the scaling requirements relative to the equivalent static procedure, with dynamic base shears of 14,901.37 kN in the X-direction and 14,901.34 kN in the Ydirection. Maximum interstory drifts of 26.23 mm and 27.84 mm in the X- and Ydirections, respectively, remain below the allowable limit of 40 mm. The maximum P-Delta stability coefficient is 0.0137, indicating no significant effect on structural stability. The building uses a Dual System comprising a Special Moment Resisting Frame (SMRF) and Special Reinforced Concrete Shear Walls. SMRF contributions to the total base shear are 43.194% in the X-direction and 30.369% in the Ydirection, satisfying the minimum requirement for a dual system. Reinforcement detailing also complies with the strength and detailing provisions of SNI 2847:2019. Therefore, the proposed design satisfies the required structural performance and seismic resistance criteria and is suitable for data center and office buildings. Keywords: Data center, Dual System, Special Moment Resisting Frame (SMRF), Reinforced Concrete Shear Wall, Response Spectrum Analysis. Perancangan struktur atas gedung data center dan kantor memerlukan sistem struktur yang mampu memenuhi persyaratan kekuatan, kekakuan, stabilitas, daktilitas, serta ketahanan terhadap beban gravitasi dan beban gempa sesuai standar yang berlaku. Penelitian ini bertujuan merencanakan struktur atas gedung data center dan kantor di Jakarta Selatan berdasarkan SNI 1726:2019, SNI 1727:2020, SNI 2847:2019, dan SNI 2052:2024, menentukan sistem struktur yang sesuai, menganalisis respons struktur terhadap pembebanan, serta merencanakan detail penulangan elemen struktur atas. Analisis dilakukan melalui pemodelan tiga dimensi menggunakan perangkat lunak ETABS v21 dengan metode Response Spectrum Analysis. Hasil penelitian menunjukkan bahwa elemen struktur atas berupa pelat, balok, kolom, dan dinding geser telah memenuhi persyaratan perencanaan sesuai standar yang digunakan. Evaluasi perilaku struktur menunjukkan bangunan tidak mengalami ketidakberaturan horizontal maupun vertikal, dengan periode fundamental sebesar 1,214 detik pada arah X dan 1,246 detik pada arah Y serta partisipasi massa kumulatif 100% pada kedua arah utama. Hasil analisis respons spektrum memenuhi ketentuan penskalaan terhadap metode statik ekuivalen, dengan gaya geser dasar dinamik sebesar 14.901,37 kN pada arah X dan 14.901,34 kN pada arah Y. Simpangan antar lantai maksimum sebesar 26,23 mm pada arah X dan 27,84 mm pada arah Y masih berada di bawah batas izin 40 mm, sedangkan koefisien stabilitas maksimum akibat efek P-Delta sebesar 0,0137, sehingga tidak berpengaruh signifikan terhadap stabilitas struktur. Struktur menggunakan Sistem Ganda (Dual System) yang mengombinasikan SRPMK dan Dinding Geser Beton Bertulang Khusus, dengan kontribusi SRPMK sebesar 43,194% pada arah X dan 30,369% pada arah Y, sehingga memenuhi persyaratan minimum sistem ganda. Detail penulangan seluruh elemen juga telah memenuhi persyaratan kekuatan dan detailing sesuai SNI 2847:2019. Dengan demikian, struktur yang dirancang dinyatakan memenuhi persyaratan kinerja struktur dan ketahanan gempa serta layak diterapkan pada bangunan data center dan kantor. Kata Kunci : Data center, Sistem Ganda, SRPMK, Dinding Geser, Respons Spektrum.
Actions (login required)
![]() |
View Item |
