ANALISIS MANAJEMEN PEMELIHARAAN PADA PLTU DI PT.XYZ (DENGAN FAKTOR MTTR, MTTF, DAN AVAILIBILITY) DAN PENYUSUNAN PROGRAM PENINGKATAN KINERJA

NURDIANSYAH, DIDA (2024) ANALISIS MANAJEMEN PEMELIHARAAN PADA PLTU DI PT.XYZ (DENGAN FAKTOR MTTR, MTTF, DAN AVAILIBILITY) DAN PENYUSUNAN PROGRAM PENINGKATAN KINERJA. S2 thesis, Universitas Mercu Buana-Menteng.

[img] Text (COVER)
55122010005-Dida Nurdiansyah-COVER - Dida Nurdiansyah.pdf

Download (615kB)
[img] Text (BAB I)
55122010005-Dida Nurdiansyah-02 BAB I - Dida Nurdiansyah.pdf
Restricted to Registered users only

Download (347kB)
[img] Text (BAB II)
55122010005-Dida Nurdiansyah-03 BAB II - Dida Nurdiansyah.pdf
Restricted to Registered users only

Download (1MB)
[img] Text (BAB III)
55122010005-Dida Nurdiansyah-04 BAB III - Dida Nurdiansyah.pdf
Restricted to Registered users only

Download (133kB)
[img] Text (BAB IV)
55122010005-Dida Nurdiansyah-05 BAB IV - Dida Nurdiansyah.pdf
Restricted to Registered users only

Download (1MB)
[img] Text (BAB V)
55122010005-Dida Nurdiansyah-06 BAB V - Dida Nurdiansyah.pdf
Restricted to Registered users only

Download (36kB)
[img] Text (DAFTAR PUSTAKA)
55122010005-Dida Nurdiansyah-08 DAFTAR PUSTAKA - Dida Nurdiansyah.pdf
Restricted to Registered users only

Download (103kB)
[img] Text (LAMPIRAN)
55122010005-Dida Nurdiansyah-09 LAMPIRAN - Dida Nurdiansyah.pdf
Restricted to Registered users only

Download (2MB)

Abstract

Data kerusakan mesin pada pembangkit listrik PT. XYZ antara Oktober-Desember 2023 menunjukkan bahwa pompa adalah komponen dengan kerusakan tertinggi, mencatat 28 kejadian (33,7% dari total 83 kerusakan), diikuti oleh kondensor dengan 27 kejadian (32,5%). Gabungan kerusakan pada kedua komponen ini mencakup 66,3% dari total kerusakan, menandakan perlunya fokus perbaikan pada pompa dan kondensor. Analisis MTTR untuk pompa menunjukkan waktu perbaikan rata-rata tinggi: 7,7 jam pada Oktober, 7 jam pada November, dan 7,7 jam pada Desember, dengan tingkat availability rendah (89,64%-89,69%). MTTF untuk pompa bervariasi dari 65,2 hingga 75,4 jam, menunjukkan kebutuhan peningkatan strategi pemeliharaan preventif. Disarankan pemeliharaan dilakukan setiap 2-3 hari atau setidaknya seminggu sekali. Kondensor memiliki MTTR antara 6,7 hingga 7,7 jam dan availability rendah (88,89%- 89,95%), dengan MTTF bervariasi dari 66,7 hingga 92,7 jam. Tingginya MTTR dan rendahnya availability pada kedua komponen ini menyoroti perlunya perbaikan dalam manajemen perawatan untuk meningkatkan kinerja. The data on machinery failures at PT. XYZ power plant from October to December 2023 highlights critical areas for improvement. The pump experienced the highest failure rate, with 28 incidents (33.7% of 83 total failures), followed closely by the condenser with 27 incidents (32.5%). Combined, these two components account for 66.3% of total failures, signaling a need for prioritized repairs. The boiler and turbine contributed 21.7% and 12.0% of failures, respectively. Focusing on repairs, the pump showed a high MTTR (Mean Time To Repair) of 7.7 hours in October, 7 hours in November, and 7.7 hours in December, with a low availability rate between 89.64% and 89.69%. These figures indicate repair delays, likely due to spare parts issues or inefficient procedures. The pump’s MTTF (Mean Time To Failure) varied from 65.2 to 75.4 hours, suggesting the need for enhanced preventive maintenance, recommended every 2-3 days or weekly. The condenser also exhibited high MTTR (6.7 to 7.7 hours) and low availability (88.89% to 89.95%), with an MTTF ranging from 66.7 to 92.7 hours, underscoring the need for improved failure management.

Item Type: Thesis (S2)
NIM/NIDN Creators: 55122010005
Uncontrolled Keywords: MTTF, MTTR, Availibility, Pemeliharaan Preventif, PemeliharaanAutonomous MTTF, MTTR, Availability, Preventive Maintenance, Autonomous Maintenance
Subjects: 600 Technology/Teknologi > 650 Management, Public Relations, Business and Auxiliary Service/Manajemen, Hubungan Masyarakat, Bisnis dan Ilmu yang Berkaitan > 658 General Management/Manajemen Umum