JABAR, ABDUL (2022) ANALISIS DEFECT BURRY SPINNING TUBE LIQUID TERHADAP POTENSI KEBOCORAN REFRIGERAN PADA SISTEM AC MOBIL MENGGUNAKAN SIMULASI KOMPUTASI ANSYS. S1 thesis, Universitas Mercu Buana Bekasi.
|
Text
41318310057 - Abdul Jabar - 01 Cover.pdf Download (1MB) | Preview |
|
|
Text
41318310057 - Abdul Jabar - 02 Abstrak.pdf Download (549kB) | Preview |
|
Text
41318310057 - Abdul Jabar - 03 BAB 1.pdf Restricted to Registered users only Download (116kB) |
||
Text
41318310057 - Abdul Jabar - 04 BAB 2.pdf Restricted to Registered users only Download (648kB) |
||
Text
41318310057 - Abdul Jabar - 05 BAB 3.pdf Restricted to Registered users only Download (588kB) |
||
Text
41318310057 - Abdul Jabar - 06 BAB 4.pdf Restricted to Registered users only Download (519kB) |
||
Text
41318310057 - Abdul Jabar - 07 BAB 5.pdf Restricted to Registered users only Download (47kB) |
||
Text
41318310057 - Abdul Jabar - 08 Daftar Pustaka.pdf Restricted to Registered users only Download (256kB) |
||
Text
41318310057 - Abdul Jabar - 09 Lampiran.pdf Restricted to Registered users only Download (145kB) |
Abstract
ABSTRAK Suatu perusahaan yang bergerak dibidang manufaktur komponen Air Conditioning mobil salah satunya yaitu tube. Tube adalah bagian yang terintegrasi didalam sistem Air Conditioning (AC) yang berfungsi sebagai sambungan yang digunakan untuk mengencangkan dan mencegah kebocoran refrigeran. Dari data tahun 2019 sampai 2021 terjadi customer claim pada tube sebanyak 63 kali salah satunya adalah kebocoran refrigeran. Penyebab kebocoran pada tube adalah adanya defect burry, scratch, dan crack. Dari ketiga jenis defect yang terjadi pada tube spinning, defect burry adalah masalah yang sering timbul dibandingkan dengan defect lain. Oleh karena itu tujuan penelitian ini adalah untuk mengetahui seberapa besar dimensi defect burry pada spinning tube liquid yang dapat membuat sistem AC mengalami kebocoran, Spesimen yang digunakan bervariasi berdasarkan dimensi tinggi dan tebal defect burry, dimensi defect burry pada spesimen 1 (0 mm - 0.05 mm), spesimen 2 (0.05 mm - 0.10 mm), spesimen 3 (0.10 mm – 0.15 mm), spesimen 4 (0.15 – 0.20 mm) dan spesimen 5 (0.20 mm – 0.25 mm). Metode yang digunakan adalah melakukan uji kebocoran pada mesin water leak test dengan tiga posisi defect burry yaitu pada posisi ujung spinning, outside spinning dan groove spinning. Kemudian dilakukan simulasi dengan memberikan tekanan 3 Mpa pada defect burry menggunakan simulasi komputasi Ansys metode static structural. Hasil dari penelitian ini adalah spesimen 2 sampai spesimen 5 mengalami kebocoran ketika posisi defect burry berada pada area outside spinning dan groove spinning, spesimen 2 paling rendah dalam menahan pembebanan sebesar 3 Mpa dengan tegangan maksimal 2.7039 Mpa dan juga didapatkan toleransi dimensi defect burry spinning tube liquid yang direkomendasikan adalah maksimal 0.05 mm karena tidak mengalami kebocoran ketika defect burry berada pada area outside spinning dan groove spinning. Kata Kunci : Air Conditioning (AC), Spinning tube, Defect burry. ABSTRACT A company engaged in the manufacture of components for car Air Conditioning, one of which is a Tube. Tube is an integrated part in the Air Conditioning (AC) system which functions as a connection used to tighten and prevent refrigerant leakage. From the data from 2019 to 2021, there were 63 customer claims on the tube, one of which was refrigerant leakage. The cause of leakage in the tube is the presence of a defect burry, scratch, and crack. Of the three types of defects that occur in tube spinning, the burry defect is a problem that often arises compared to other defects. Therefore, the purpose of this study was to determine how big the dimensions of the defect burry in the spinning tube liquid can cause the AC system to leak. The specimens used vary based on the dimensions of the height and thickness of the defect burry, and the dimensions of the defect burry in specimen 1 (0 mm - 0.05 mm). ), specimen 2 (0.05 mm - 0.10 mm), specimen 3 (0.10 mm – 0.15 mm), specimen 4 (0.15 – 0.20 mm) and specimen 5 (0.20 mm – 0.25 mm). The method used is to perform a leak test on a water leak test machine with three defect burry positions, namely at the spinning end position, outside spinning and spinning groove. Then a simulation is carried out by applying a pressure of 3 MPa to the defect burry using an ansys computational simulation of the static structural method. The results of this study are that specimens 2 to 5 have leaks when the position of the defect burry is in the outside spinning and groove spinning area, specimen 2 is the lowest in resisting pressure of 3 Mpa with a maximum stress of 2.7039 Mpa and the recommended dimensional tolerance of the defect burry spinning tube liquid is a maximum of 0.05 mm because it does not leak when the defect burry is in an area outside the spinning and spinning groove. Keywords : Air Conditioning (AC), Spinning tube, Defects burry.
Item Type: | Thesis (S1) |
---|---|
Call Number CD: | FT/MSN 22 017 |
NIM/NIDN Creators: | 41318310057 |
Uncontrolled Keywords: | Kata Kunci : Air Conditioning (AC), Spinning tube, Defect burry. |
Subjects: | 600 Technology/Teknologi > 620 Engineering and Applied Operations/Ilmu Teknik dan operasi Terapan > 621 Applied Physics/Fisika terapan > 621.8 Machine Engineering, Machinery/Teknik Mesin |
Divisions: | Fakultas Teknik > Teknik Mesin |
Depositing User: | siti maisyaroh |
Date Deposited: | 22 Dec 2022 05:03 |
Last Modified: | 22 Dec 2022 05:03 |
URI: | http://repository.mercubuana.ac.id/id/eprint/72693 |
Actions (login required)
View Item |