JUWARI, ANWAR SALEH (2019) ANALISA GANGGUAN GENERATOR GROUND FAULT PADA ROTOR GENERATOR MENGGUNAKAN RECCURENT SURGE OSCILOSCOPE. S1 thesis, Universitas Mercu Buana Jakarta.
|
Text (HAL COVER)
1. Halaman Judul.pdf Download (40kB) | Preview |
|
|
Text (ABSTRAK)
2. Abstract.pdf Download (28kB) | Preview |
|
|
Text (LEMBAR PERNYATAAN)
3. Lembar Pernyataan.pdf Download (183kB) | Preview |
|
|
Text (LEMBAR PENGESAHAN)
4. Lembar Pengesahan.pdf Download (150kB) | Preview |
|
|
Text (KATA PENGANTAR)
5. Kata Pengantar.pdf Download (96kB) | Preview |
|
|
Text (DAFTAR ISI)
6. DAFTAR ISI.pdf Download (373kB) | Preview |
|
|
Text (DAFTAR TABEL)
7. Daftar Tabel.pdf Download (195kB) | Preview |
|
|
Text (DAFTAR GAMBAR)
8. DAFTAR GAMBAR.pdf Download (202kB) | Preview |
|
Text (BAB I)
9. BAB I.pdf Restricted to Registered users only Download (182kB) |
||
Text (BAB II)
10. BAB II.pdf Restricted to Registered users only Download (580kB) |
||
Text (BAB III)
11. BAB III.pdf Restricted to Registered users only Download (867kB) |
||
Text (BAB IV)
12. BAB IV.pdf Restricted to Registered users only Download (852kB) |
||
Text (BAB V)
13. BAB V .pdf Restricted to Registered users only Download (66kB) |
||
Text (DAFTAR PUSTAKA)
14. Daftar Pustaka.pdf Restricted to Registered users only Download (67kB) |
||
Text (LAMPIRAN)
15. Lampiran.pdf Restricted to Registered users only Download (889kB) |
Abstract
The problem that occurs in one of the generator rotors is the presence of a ground fault winding rotor generator due to insulating damage on the wrong winding. This problem is due to thermal factors or because of the level of insulation that starts to decline or has been damaged. To detect the existence of these problems, it is necessary to test with the Reccurent Surge Oscilloscope. Tests are carried out to determine the location of the fault and the impedance deviation value. The ground fault that occurred in Mount Salak PLTP unit 3 was a ground fault that occurred when the rotor generator rotated 1000 rpm. To identify the disturbances used the Reccurent Surge Oscilloscope test method before and after repairs, as long as the test results have not shown any graphs that coincide, it is said that the generator still has ground fault. Besides the measurement of the rotor windings before and after repairs based on the IEEE Std 56-1997 standard (standard deviation of 3%). From the results of the Testing the Reccurent Surge Oscilloscope shows interference with coils 2A, 3A, 4A, 5A, 7A, 6B and 7B. Ground fault on the generator rotor is caused by damage to the insulation between the rotor windings and the retaining ring. Thus causing a deviation of 34.7%. Then after the isolation replacement, the results of the graphical Oscilloscope Reccurent Surge test showed no damage and the deviation value was 2.2%. With the improvement of insulation, the deviation value was reduced by 32.5%. Keywords: Rotor Generator, Ground Fault, Reccurent Surge Oscilloscope, deviation, IEEE Std 56-1997. Permasalahan yang terjadi pada salah satu rotor generator adalah adanya generator ground fault winding rotor dikarenakan adanya kerusakan isolasi pada salah belitan. Permasalahan ini dikarenakan faktor thermal atau karena tingkat isolasi yang mulai menurun atau sudah rusak. Untuk mendeteksi adanya permasalahan tersebut perlu dilakukan pengujian dengan Reccurent Surge Oscilloscope. Pengujian dilakukan dilakukan untuk mengetahui lokasi gangguan dan nilai deviasi impedansi. Gangguan ground fault yang terjadi di PLTP Gunung Salak unit 3 merupakan gangguan ground fault yang terjadi pada saat rotor generator berputar 1000 rpm. Untuk mengidentikasi gangguan digunakan metode pengujian Reccurent Surge Oscilloscope sebelum dan sesudah perbaikan, selama hasil pengujian belum menunjukkan adanya grafik yang berhimpit maka dikatakan generator masih terjadi gangguan ground fault. Selain itu pengukuran pada belitan rotor sebelum dan sesudah perbaikan berdasarkan standart IEEE Std 56-1997 (standart deviasi 3%). Dari hasil Pengujian Reccurent Surge Oscilloscope menunjukkan adanya gangguan pada koil 2A, 3A, 4A, 5A, 7A, 6B dan 7B. Ground fault pada rotor generator disebabkan adanya kerusakan isolasi antara belitan rotor terhadap retaining ring. Sehingga menyebabkan terjadinya deviasi sebesar 34,7 %. Kemudian setelah dilakukan penggantian isolasi, hasil pengujian Reccurent Surge Oscilloscope grafik menunjukkan tidak adanya kerusakan dan nilai deviasi menjadi 2,2 %. Dengan dilakukan perbaikan isolasi menyebabkan nilai deviasi berkurang sebesar 32,5 %. Kata Kunci : Rotor Generator, Ground Fault, Reccurent Surge Oscilloscope, deviasi , IEEE Std 56-1997.
Actions (login required)