PUTRA, ERVIN SURYA IRAMA (2018) ANALISA PERFORMANCE MEDIA TRAINER AC CENTRAL MENGGUNAKAN REFRIGERANT R-22. S1 thesis, Universitas Mercu Buana Bekasi.
|
Text
1. Halaman Judul.pdf Download (37kB) | Preview |
|
|
Text
2. Abstrak.pdf Download (165kB) | Preview |
|
|
Text
3. Surat Pernyataan.pdf Download (68kB) | Preview |
|
|
Text
4. Lembar Pengesahan.pdf Download (55kB) | Preview |
|
|
Text
5. Kata Pengantar.pdf Download (36kB) | Preview |
|
|
Text
6. Lembar Penghargaan.pdf Download (41kB) | Preview |
|
|
Text
7. Daftar Isi.pdf Download (28kB) | Preview |
|
|
Text
8. Daftar Gambar.pdf Download (100kB) | Preview |
|
|
Text
9. Daftar Tabel.pdf Download (99kB) | Preview |
|
Text
10. BAB I.pdf Restricted to Registered users only Download (259kB) |
||
Text
11. BAB II.pdf Restricted to Registered users only Download (536kB) |
||
Text
12. BAB III.pdf Restricted to Registered users only Download (377kB) |
||
Text
13. BAB IV.pdf Restricted to Registered users only Download (610kB) |
||
Text
14 BAB V.pdf Restricted to Registered users only Download (164kB) |
||
Text
15. DAFTAR PUSTAKA.pdf Restricted to Registered users only Download (330kB) |
Abstract
ABSTRAK Pengkondisian udara disebut juga system refrigerasi yang mengatur temperature & kelembaban udara. Dalam beroperasi system refrigerasi membutuhkan fluida yang mudah menyerap dan melepas kalor, yang disebut refrigeran. Setiap refrigerant memiliki sifat karakteristik yang berbeda yang mempengaruhi efek refrigerasi dan koefeisien prestasi yang dihasilkan. R 22 adalah refrigerant yang memiliki karakteristik yang baik pada mesin pendingin. Refrigerant tersebut banyak dijumpai pada penggunaan mesin pendingin baik refrigerator (lemari es) maupun AC (air conditioner). .Pengujian kali ini dilakukan dengan menambahan beban pada AC untuk mengetahui unjuk kerja kompresor, kapastias pendingin, dan COP AC. Dari Hasil Percobaan yang telah dilakukan pada Media AC Central. Dengan Bertambahnya beban pendigin, maka unjuk kerja kompresor semkain berat. Kapasitas pendingin mengalami penurunan, sehingga hal ini menyebabkan COP AC menjadi lebih buruk. Air conditioning is also called a refrigeration system that regulates temperature & humidity. In operating a refrigeration system requires fluids that easily absorb and release heat, called refrigerants. Each refrigerant has different characteristic properties that affect the effects of refrigeration and the resulting performance coefficients. R 22 is a refrigerant that has good characteristics on cooling machines. The refrigerant is often found in the use of either refrigerator refrigeration machines (refrigerators) or air conditioners. This time the test is done by increasing the load on the air conditioner to determine the performance of the compressor, cooling capacity, and AC AC. From the results of the experiments that have been carried out on the Central AC Media. With the increasing load of pendigin, the performance of the compressor is as heavy as it is. Cooling capacity has decreased, so this causes the AC COP to become worse.
Item Type: | Thesis (S1) |
---|---|
Call Number CD: | FT/MSN 18 017 |
NIM/NIDN Creators: | 41316320024 |
Subjects: | 600 Technology/Teknologi > 620 Engineering and Applied Operations/Ilmu Teknik dan operasi Terapan > 621 Applied Physics/Fisika terapan > 621.8 Machine Engineering, Machinery/Teknik Mesin |
Divisions: | Fakultas Teknik > Teknik Mesin |
Depositing User: | siti maisyaroh |
Date Deposited: | 21 Jul 2022 08:04 |
Last Modified: | 21 Jul 2022 08:04 |
URI: | http://repository.mercubuana.ac.id/id/eprint/65791 |
Actions (login required)