AZZAHRA, ANISA (2020) SIMULASI DAN ANALISA LINK FAILOVER SEBAGAI BACK UP LINK PADA JARINGAN MULTI PROTOCOL LABEL SWITCHING (MPLS) MENGGUNAKAN ROUTING BORDER GATEWAY PROTOCOL (BGP). S1 thesis, Universitas Mercu Buana Bekasi.
|
Text
1. Halaman Judul.pdf Download (110kB) | Preview |
|
|
Text
2. Lembar Pernyataan.pdf Download (506kB) | Preview |
|
|
Text
3. Lembar Pengesahan.pdf Download (246kB) | Preview |
|
|
Text
4. Kata Pengantar.pdf Download (148kB) | Preview |
|
|
Text
5. Abstrak.pdf Download (148kB) | Preview |
|
|
Text
6. Daftar Isi.pdf Download (111kB) | Preview |
|
|
Text
7. Daftar Gambar.pdf Download (106kB) | Preview |
|
|
Text
8. Daftar Tabel.pdf Download (103kB) | Preview |
|
|
Text
9. Daftar lampiran.pdf Download (21kB) | Preview |
|
Text
10. Bab 1.pdf Restricted to Registered users only Download (113kB) |
||
Text
11. Bab 2.pdf Restricted to Registered users only Download (497kB) |
||
Text
12. Bab 3.pdf Restricted to Registered users only Download (312kB) |
||
Text
13. Bab 4.pdf Restricted to Registered users only Download (277kB) |
||
Text
14. Bab 5.pdf Restricted to Registered users only Download (107kB) |
||
Text
15. Daftar Pustaka.pdf Restricted to Registered users only Download (141kB) |
||
Text
16. Lampiran.pdf Restricted to Registered users only Download (472kB) |
Abstract
ABSTRAK Dengan penggunaan internet yang begitu banyak saat ini dituntut untuk ketersedian link secara terus – menerus agar dapat melakukan pertukaran data dan informasi secara mudah dan cepat. Failover merupakan salah satu cara yang dapat digunakan sebagai backup link ketika salah satu koneksi internet mengalami gangguan. Pada penelitian ini link failover sebagai backup link pada jaringan Multi Protocol Label Switcing (MPLS) menggunakan Border Gateway Protocol (BGP) sebagai routing protocolnya. Pada perancangan sistem ini digunakan empat buah router yang terdiri dari router CE untuk mengatur sistem failover menuju ke dua buah router PE sebagai jalur dari dua ISP yang berbeda dan router pada kantor pusat sebagai gateway dari server. Tiap router tersebut memiliki Autonomus System Number yang berbeda yang saling berkomunikasi menggunakan routing BGP. Dari hasil simulasi sistem failover, saat interfaces mainlink di matikan maka link dapat berpindah ke jalur backup secara otomatis dengan menggunakan routing BGP. Hasil simulasi sistem failover menggunakan routing BGP pada saat koneksi dual link didapatkan nilai parameter throughput 1658 bps , delay 244.6 ms, jitter 0.23 ms dan packet loss 0%. Sedangkan hasil simulasi sebelum menggunakan sistem failover atau saat koneksi single link didapatkan nilai parameter throughput 1551 bps , delay 259.2 ms, jitter 0.25 ms dan packet loss 0%. Dengan adanya sistem failover menggunakan routing BGP didapatkan hasil yang lebih baik pada saat menggunakan koneksi dual link dibandingkan saat menggunakan koneksi single link. Kata Kunci: Link Failover, Routing BGP, QoS. ABSTRACT With the use of the internet so much at this time, demanded for the availability of links continuously - in order to exchange data and information easily and quickly. Failover is one way that can be used as a backup link when one internet connection is interrupted. In this study the failover link on the Multi Protocol Label Switcing (MPLS) network uses the Border Gateway Protocol (BGP) as its routing protocol. In designing this system, there are four routers are used, consisting of a CE router to manage the failover system to two PE routers as a path from two different ISPs and a router at the central office as the gateway of the server. Each router has a different Autonomus System Number that communicates with each other using BGP routing. From the results of a failover system simulation, when the mainlink interfaces are switched off, the link successfully moves to the backup path automatically using BGP routing. The results of a failover system simulation using BGP routing when the dual link connection is obtained throughput parameters 1658 bps, delay 244.6 ms, jitter 0.23 ms and packet loss 0%. While the simulation results before using a failover system or when a single link connection is obtained throughput parameters 1551 bps, delay 259.2 ms, jitter 0.25 ms and packet loss 0%. With a failover system using BGP routing, it gets better results when using a dual link connection than when using a single link connection. Keywords: Link Failover, BGP Routing, QoS.
Item Type: | Thesis (S1) |
---|---|
Call Number CD: | FE/ELK 20 033 |
NIM/NIDN Creators: | 41418320005 |
Uncontrolled Keywords: | Kata Kunci: Link Failover, Routing BGP, QoS. |
Subjects: | 600 Technology/Teknologi > 620 Engineering and Applied Operations/Ilmu Teknik dan operasi Terapan > 621 Applied Physics/Fisika terapan > 621.3 Electrical Engineering, Lighting, Superconductivity, Magnetic Engineering, Applied Optics, Paraphotic Technology, Electronics Communications Engineering, Computers/Teknik Elektro, Pencahayaan, Superkonduktivitas, Teknik Magnetik, Optik Terapan, Tekn |
Divisions: | Fakultas Teknik > Teknik Elektro |
Depositing User: | siti maisyaroh |
Date Deposited: | 15 Jun 2022 07:01 |
Last Modified: | 15 Jun 2022 07:01 |
URI: | http://repository.mercubuana.ac.id/id/eprint/63409 |
Actions (login required)
View Item |