ANALISIS LOSSES DAN THD (TOTAL HARMONIC DISTORTION) AKIBAT PENGARUH BEBAN NON LINEAR PADA TRANSFORMATOR DAYA

PURNOMO, ANDRI (2020) ANALISIS LOSSES DAN THD (TOTAL HARMONIC DISTORTION) AKIBAT PENGARUH BEBAN NON LINEAR PADA TRANSFORMATOR DAYA. S2 thesis, Universitas Mercu Buana Jakarta-Menteng.

[img]
Preview
Text (HALAMAN JUDUL)
1 Halaman Judul Andri Purnomo.pdf

Download (410kB) | Preview
[img]
Preview
Text (ABSTRAK)
2 Abstrak Andri Purnomo.pdf

Download (501kB) | Preview
[img]
Preview
Text (LEMBAR PENGESAHAN)
3 LEMBAR PENGESAHAN Andri Purnomo.pdf

Download (397kB) | Preview
[img]
Preview
Text (PERNYATAAN KEASLIAN)
4 PERNYATAAN KEASLIAN Andri Purnomo.pdf

Download (419kB) | Preview
[img]
Preview
Text (SIMILARITY CHECK)
5 SIMILARITY CECK Andri Purnomo.pdf

Download (390kB) | Preview
[img]
Preview
Text (KATA PENGANTAR)
6 Kata Pengantar Andri Purnomo.pdf

Download (145kB) | Preview
[img]
Preview
Text (DAFTAR ISI)
7 Daftar Isi Andri Purnomo.pdf

Download (432kB) | Preview
[img]
Preview
Text (DAFTAR TABEL)
8 Daftar Tabel Andri Purnomo.pdf

Download (541kB) | Preview
[img]
Preview
Text (DAFTAR GAMBAR)
9 Daftar Gambar Andri Purnomo.pdf

Download (429kB) | Preview
[img]
Preview
Text (DAFTAR LAMPIRAN)
10 Daftar Lampiran Andri Purnomo.pdf

Download (1MB) | Preview
[img] Text (BAB 1)
BAB 1 Andri Purnomo.pdf
Restricted to Registered users only

Download (820kB)
[img] Text (BAB 2)
BAB 2 Andri Purnomo.pdf
Restricted to Registered users only

Download (1MB)
[img] Text (BAB 3)
BAB 3 Andri Purnomo.pdf
Restricted to Registered users only

Download (825kB)
[img] Text (BAB 4)
BAB 4 Andri Purnomo.pdf
Restricted to Registered users only

Download (1MB)
[img] Text (BAB 5)
BAB 5 Andri Purnomo.pdf
Restricted to Registered users only

Download (563kB)
[img] Text (DAFTAR PUSTAKA)
DAFTAR PUSTAKA Andri Purnomo.pdf
Restricted to Registered users only

Download (371kB)
[img] Text (LAMPIRAN)
LAMPIRAN Andri Purnomo.pdf
Restricted to Registered users only

Download (2MB)

Abstract

The Total Harmonic Distortion (THD) voltage and current do not meet IEEE 519- 2014 standard can be losses to the power transformer, so that it will can be interference with the electric power system.The research try to analyze losses and THD (Total Harmonic Distortion) because of nonlinear loads and compare with measurement results using a power quality analyzer and ETAP simulation. Based on THDv and THDi from the result measurement and simulation, obtained difference THDv of 0.13% and THDi of 0.62%. The result indicated the electricity data obtained for simulation are almost in accordance with field condition. At peak load conditions between 6:00 a.m. to 9:30 p.m. measurements were carried out using a power quality analyzer at time interval of 5 minutes each with total average THDi of a minimum of 6.59 and a maximum of 4.78, and a minimum total average of 1.6886 and a maximum of 1.8535. The condition show is THDi high then losses increased. Keywords: THD (Total harmonic distortion), Losses, Non Linear Loads

Item Type: Thesis (S2)
Call Number CD: CDT-554-20-020
Call Number: T-54-MTE-20-006
NIM/NIDN Creators: 55416120016
Uncontrolled Keywords: THD (Total harmonic distortion), Losses, Non Linear Loads
Subjects: 600 Technology/Teknologi > 620 Engineering and Applied Operations/Ilmu Teknik dan operasi Terapan > 621 Applied Physics/Fisika terapan
Divisions: Pascasarjana > Magister Teknik Elektro
Depositing User: ORYZA LUVITA
Date Deposited: 21 Feb 2022 03:15
Last Modified: 18 Jun 2022 06:17
URI: http://repository.mercubuana.ac.id/id/eprint/56408

Actions (login required)

View Item View Item