PUTRA, ARDYAN ARFAL (2019) ANALISA TEGANGAN SAG AKIBAT GANGGUAN ARUS HUBUNG SINGKAT PADA PERENCANAAN PROYEK THEME PARK PARAHYANGAN BANDUNG. S1 thesis, Universitas Mercu Buana.
|
Text (HALAMAN COVER)
1. Halaman Judul.pdf Download (81kB) | Preview |
|
|
Text (ABSTRAK)
5. Abstrak.pdf Download (149kB) | Preview |
|
|
Text (LEMBAR PERNYATAAN)
2. Lembar Pernyataan.pdf Download (73kB) | Preview |
|
|
Text (LEMBAR PENGESAHAN)
3. Lembar Pengesahan.pdf Download (77kB) | Preview |
|
|
Text (KATA PENGANTAR)
4. Kata Pengantar.pdf Download (102kB) | Preview |
|
|
Text (DAFTAR ISI)
6. Daftar Isi.pdf Download (87kB) | Preview |
|
|
Text (DAFTAR TABEL)
8. Daftar Tabel.pdf Download (81kB) | Preview |
|
|
Text (DAFTAR GAMBAR)
7. Daftar Gambar.pdf Download (95kB) | Preview |
|
|
Text (DAFTAR LAMPIRAN)
9. Daftar Lampiran.pdf Download (68kB) | Preview |
|
Text (BAB 1)
10. BAB I Pendahuluan.pdf Restricted to Registered users only Download (138kB) |
||
Text (BAB 2)
11. BAB II Landasan Teori.pdf Restricted to Registered users only Download (603kB) |
||
Text (BAB 3)
12. BAB III Metodologi Penelitian.pdf Restricted to Registered users only Download (291kB) |
||
Text (BAB 4)
13. BAB IV Hasil Dan Pembahasan.pdf Restricted to Registered users only Download (364kB) |
||
Text (BAB 5)
14. BAB V Kesimpulan dan Saran.pdf Restricted to Registered users only Download (123kB) |
||
Text (DAFTAR PUSTAKA)
15. Daftar Pustaka.pdf Restricted to Registered users only Download (129kB) |
||
Text (LAMPIRAN)
16. Lampiran.pdf Restricted to Registered users only Download (1MB) |
Abstract
In the distribution of electrical energy in the distribution system of medium voltage networks or low voltage networks, the quality of the power to be distributed must be maintained. In addition, the level of reliability and security in delivering electrical power including at the time of continue and in the event of a disturbance must be considered and designed in such a way. This is done to maintain the value of the quality of electricity to be produced so that it still has good voltage quality. In the operation of an electric power system there are frequent disturbances that can result in disruption of electrical power distribution to electrical equipment. One of the disturbances in the electric power system that often occurs is short circuit or short circuit which at the time of the short circuit current there is a decrease in voltage along with the occurrence of short circuit which is commonly called the sag voltage or blinking voltage. Many occurrences of electrical equipment and electronic equipment are damaged during and after the occurrence of short circuit currents, so that the presence of these damage can cause considerable losses. To calculate the sag voltage, the step that must be done is to calculate the short circuit current first. Electrical system diagram blocks that have been made, consisting and composed of a series of electrical equipment equipment that make up a system. The electrical system diagram block is then simulated into the ETAP 12.6 application, an application to simulate an electric power system and the short circuit current will be known. Point faults location for sag voltage analysis are on PDTR-1, MP-P1.2 & MP-P.1.3 buses. Based on the calculation results, the 3 phase short circuit current on the PDTR-1 bus is 32.46 ∠ 74.75 ° kA, on the MP-P.1.2 bus it is 7.69∠-41.76 ° kA and on the bus MP-P.1.3 is 4,56∠-38,20 ° kA. While the calculation of the phase 3 sag 3 voltage on the PDTR-1 bus is 283,57∠-74.75 ° V or 41.21%, on the MP-P.1.2 bus it is 326,07∠-41,76 ° V or 47.39% and the MPP. 1.3 bus is 324.31∠-38.20 ° V or 47.13%. Keywords: Short Circuit, Voltage Sag, Electrical System Dalam penyaluran energi listrik pada sistem distribusi jaringan tegangan menengah atau jaringan tegangan rendah perlu dijaga nilai kualitas dari daya yang akan disalurkan. Selain itu, tingkat keandalan dan keamanan dalam menyalurkan tenaga listrik termasuk pada saat continue maupun pada saat terjadi gangguan harus diperhatikan dan di desain sedemikian rupa. Hal tersebut dilakukan untuk menjaga nilai dari mutu listrik yang akan dihasilkan agar tetap memiliki kualitas tegangan yang baik. Dalam operasi sistem tenaga listrik sering terjadi gangguan-gangguan yang dapat mengakibatkan terganggunya penyaluran tenaga listrik ke peralatan-peralatan listrik. Salah satu gangguan dalam sistem tenaga listrik yang sering terjadi adalah arus hubung singkat atau short circuit yang mana pada saat terjadinya arus hubung singkat terdapat penurunan tegangan seiring dengan terjadinya hubung singkat yang biasa disebut dengan tegangan sag atau tegangan kedip. Banyak kejadian peralatan listrik dan peralatan elektronik mengalami kerusakan pada saat dan setelah terjadinya arus hubung singkat, sehingga dengan adanya kerusakan-kerusakan tersebut dapat menyebabkan kerugian yang cukup besar. Untuk menghitung tegangan sag, langkah yang harus dilakukan adalah menghitung arus hubung singkat terlebih dahulu. Blok diagram sistem elektrikal yang sudah dibuat, terdiri dan tersusun dari rangkaian peralatan peralatan listrik yang membentuk suatu sistem. Blok diagram sistem elektrikal tersebut lalu disimulasikan ke dalam aplikasi ETAP 12.6, sebuah aplikasi untuk mensimulasikan sistem tenaga listrik dan akan diketahui besarnya arus hubung singkat. Titik lokasi gangguan untuk analisis tegangan sag adalah pada bus PDTR-1, MPP1.2 & MP-P.1.3. Berdasarkan hasil perhitungan, arus hubung singkat 3 fasa yang pada bus PDTR-1 adalah sebesar 32,46∠-74,75° kA, pada bus MP-P.1.2 adalah sebesar 7,69∠- 41,76° kA dan pada bus MP-P.1.3 adalah sebesar 4,56∠-38,20° kA. Sedangkan hasil perhitungan tegangan sag 3 fasa fasa pada bus PDTR-1 adalah sebesar 283,57∠-74,75° V atau 41,21% , pada bus MP-P.1.2 adalah sebesar 326,07∠-41,76° V atau 47,39% dan pada bus MP-P.1.3 adalah sebesar 324,31∠-38,20° V atau 47,13%. Kata Kunci: Hubung Singkat, Tegangan Kedip, Sistem Kelistrikan