Abstract
A two-way plate is an efficient, economical, and large structure. A concrete plate is sustained in all four sides. One type of two-way plate is a Flat Slab. The flat slab is a construction reinforced concrete slab structure that transfers the load directly to the supported column without the help of beam elements. The failure that usually occurred in this flat slab structure is the punching shear failure, caused by forces that working around the column. The punching shear failure can be reduced by increasing the thickening around the column (drop panel) or increasing the column dimension. In the discussion of this final project, it will be analyzed to find out the amount of punching shear force in the flat slab, the influence of earthquake load against the flat slab, and discuss the influence of the shear force between the connection of plate and column. The discussion of this final project aims to discover the influence in the use of drop panel in the flat slab construction against the punching shear failure and considering the earthquake forces. The conclusions obtained are the use of drop panel in the flat slab can reduce the punching shear failure. The connection between plate and column is very susceptible to shear failure. This plan will be safe to the shear, even two-way or one-way shear, and a combination of shear and moment. Keyword: Two Way Slab, Flat Slab system, Drop Panel, Shear Failure, Shear Capacity Pelat dua-arah adalah struktur yang efesien, ekonomis, dan luas. Pelat beton ditopang di keempat sisinya. Salah satu jenis pelat dua arah yaitu Flat Slab. Flat slab adalah konstruksi struktur pelat beton bertulang yang mentransfer beban langsung ke kolom pendukung tanpa bantuan elemen balok. Kegagalan yang biasanya terjadi pada struktur flat slab ini adalah kegagalan geser pons, yang diakibatkan karena gaya yang bekerja di sekitar kolom. Kegagalan geser pons dapat di reduksi dengan penambahan penebalan di sekitar kolom (drop panel) atau dengan penambahan dimensi kolom. Pada pembahasan dalam Tugas Akhir ini dilakukan analisis untuk mencari besarnya gaya geser pons pada flat slab dan pengaruh beban gempa terhadap flat slab, serta membahas pengaruh gaya geser pada sambungan antara pelat dan kolom. Pembahsan dalam Tugas akhir ini bertujuan untuk mengetahui pengaruh penggunaan drop panel pada konstruksi Flat slab terhadap kegagalan geser pons. Serta memperhitungkan gaya gempa. Kesimpulan yang didapat adalah penggunaan Drop panel pada flat slab dapat mereduksi kegagalan geser pons. Sambungan antara pelat dan kolom sangat rentan terhadap kegagalan geser pada perencanaan ini aman terhadap geser, baik geser dua arah, geser satu arah, maupun terhadap kombinasi geser dan momen. Kata Kunci: Pelat Dua Arah, Sistem Flat Slab, Drop Panel, Kegagaalan Geser, Kapasitas Geser.
Actions (login required)
View Item |