AUDIT ENERGI DAN ANALISIS PELUANG PENGHEMATAN KONSUMSI ENERGI PADA GEDUNG HOTEL AMARIS MANGGA – BESAR

HARYANTO, DWI (2012) AUDIT ENERGI DAN ANALISIS PELUANG PENGHEMATAN KONSUMSI ENERGI PADA GEDUNG HOTEL AMARIS MANGGA – BESAR. S1 thesis, Universitas Mercu Buana Jakarta.

[img]
Preview
Text (HAL COVER)
01 HAL COVER.pdf

Download (168kB) | Preview
[img]
Preview
Text (ABSTRAK)
02 ABSTRACT.pdf

Download (57kB) | Preview
[img] Text (BAB I)
03 BAB I.pdf
Restricted to Registered users only

Download (67kB)
[img] Text (BAB II)
04 BAB II.pdf
Restricted to Registered users only

Download (538kB)
[img] Text (BAB III)
05 BAB III.pdf
Restricted to Registered users only

Download (848kB)
[img] Text (BAB IV)
06 BAB IV.pdf
Restricted to Registered users only

Download (60kB)
[img] Text (DAFTAR PUSTAKA DAN LAMPIRAN)
DAFTAR PUSTAKA&LAMPIRAN.pdf
Restricted to Registered users only

Download (4MB)

Abstract

Audit Energi pada Gedung Hotel Amaris Mangga Besar difokuskan pada perincian penggunaan energi listrik, metode yang digunakan adalah mengacu pada “Prosedur Audit Energi Pada Bangunan Gedung SNI 03-6196-2000”. Setelah dilakukan Audit Energi Awal didapatkan hasil 139,48 kWH/m2 year masih jauh lebih kecil dari standar ASEAN-USAID yaitu 300 kWH/m2 year. Dengan melakukan Analisis PHE (Peluang Hemat Energi) didapatkan penggunaan energi listrik pada Air Conditioning mencapai 51% dari total penggunaan energi listrik.

Item Type: Thesis (S1)
Call Number CD: FT/MSN. 12 017
Call Number: STI/13/12/017
NIM/NIDN Creators: 41307110005
Uncontrolled Keywords: Audit Energi, Air Conditioning, Peluang Hemat Energi
Divisions: Fakultas Teknik > Teknik Mesin
Depositing User: Admin Perpus UMB
Date Deposited: 26 Mar 2012 16:57
Last Modified: 10 Dec 2025 07:00
URI: http://repository.mercubuana.ac.id/id/eprint/17958

Actions (login required)

View Item View Item